{"title":"Low Temperature Fluids","description":"","products":[{"product_id":"tmc-49-specialty-fluid","title":"TMC-49 Specialty Fluid","description":"\u003ch2\u003eAdvanced Dielectric Heat Transfer Fluid\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTMC-49 Specialty Fluid\u003c\/strong\u003e is a premium \u003cstrong\u003especialty fluid\u003c\/strong\u003e engineered for advanced thermal management, immersion cooling, and electronic cleaning applications. Developed by \u003cstrong\u003eTMC Industries\u003c\/strong\u003e, this high-performance hydrofluoroolefin (HFO)-based dielectric fluid delivers exceptional heat transfer efficiency while maintaining excellent electrical insulation properties. It is designed for modern high-power computing environments, data centers, semiconductor manufacturing, and industrial electronics where reliable cooling and operational safety are critical.\u003c\/p\u003e\n\u003cp\u003eWith its \u003cstrong\u003enon-flammable\u003c\/strong\u003e, \u003cstrong\u003elow-viscosity\u003c\/strong\u003e, and \u003cstrong\u003ewater-free\u003c\/strong\u003e formulation, TMC-49 enables efficient two-phase immersion cooling, reducing heat buildup and improving overall equipment reliability. The fluid features \u003cstrong\u003eZero Ozone Depletion Potential (ODP)\u003c\/strong\u003e and a \u003cstrong\u003eGlobal Warming Potential (GWP) of 20\u003c\/strong\u003e, making it a more environmentally responsible choice for next-generation cooling technologies. It is suitable for direct immersion cooling systems, high-performance servers, electronic components, and precision industrial equipment requiring stable thermal performance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh thermal stability for continuous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltra-low viscosity for improved heat transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcellent dielectric strength for electrical insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-flammable with no flash point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-corrosive and water-free formulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow evaporation characteristics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong operational service life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZero Ozone Depletion Potential (ODP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow Global Warming Potential (GWP 20)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits Heat Transfer Fluid\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDelivers superior cooling efficiency in high-density electronic systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImproves the lifespan of electronic equipment and processors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduces maintenance requirements and operating costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports improved energy efficiency and lower power consumption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains reliable performance in demanding operating environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for both new installations and retrofit immersion cooling systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eTMC-49 Specialty Fluid is widely used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eData Centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImmersion Cooling Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEV Battery Cooling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectronics Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Industry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedical Equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAerospace \u0026amp; Defense Electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Heat Transfer Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLaboratory Equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupercomputing Centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy Storage Power Centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectronic Component Cleaning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppearance\u003c\/td\u003e\n\u003ctd\u003eLiquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eColorless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurity\u003c\/td\u003e\n\u003ctd\u003e≥99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDensity\u003c\/td\u003e\n\u003ctd\u003e1.60 g\/cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViscosity\u003c\/td\u003e\n\u003ctd\u003e0.356 mm²\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoiling Point\u003c\/td\u003e\n\u003ctd\u003e47°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Point\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFreezing Point\u003c\/td\u003e\n\u003ctd\u003e-80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e43.4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Constant\u003c\/td\u003e\n\u003ctd\u003e1.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Content\u003c\/td\u003e\n\u003ctd\u003e≤100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eIndustries Served\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAutomotive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectronics Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTelecommunications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRenewable Energy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAerospace \u0026amp; Defense\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedical Equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Center Infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSemiconductor Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose TMC-49 Specialty Fluid?\u003c\/h2\u003e\n\u003cp\u003eTMC-49 has been engineered for modern high-performance computing and industrial cooling environments where traditional cooling fluids may not provide sufficient efficiency. Its advanced dielectric properties protect sensitive electronic components while delivering excellent heat transfer performance.\u003c\/p\u003e\n\u003cp\u003eKey advantages include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePremium HFO-based formulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrusted performance from TMC Industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmentally responsible design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong service life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCost-effective thermal management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for immersion cooling and precision cleaning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with a wide range of industrial materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSafety \u0026amp; Storage\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStore in a cool, dry, well-ventilated area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep containers tightly sealed after use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShelf life: \u003cstrong\u003e5 years\u003c\/strong\u003e in original unopened packaging under normal storage conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow recommended PPE and handling practices as outlined in the Safety Data Sheet (SDS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid mixing with incompatible chemicals and contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePackaging Options\u003c\/h2\u003e\n\u003cp\u003eAvailable packaging includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 kg Sample\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Gallon Jug\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 Gallon Pail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e55 Gallon Drum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e275 Gallon Tote (Available on Request)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003ch3\u003eCompatible Materials\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCopper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStainless Steel (304L \u0026amp; 316L)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBrass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTitanium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePolyethylene (PE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePTFE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePolyimide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSilicone Rubber\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEpoxy Resin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvoid or Use with Caution\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLithium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSodium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePotassium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMagnesium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEPDM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePolyurethane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAcrylic (PMMA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHNBR\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003eIs TMC-49 electrically non-conductive?\u003c\/h3\u003e\n\u003cp\u003eYes. It is a dielectric specialty fluid designed for immersion cooling and sensitive electronic equipment.\u003c\/p\u003e\n\u003ch3\u003eCan the fluid be reused?\u003c\/h3\u003e\n\u003cp\u003eYes. Under recommended operating conditions, the fluid can be reclaimed and reused following proper maintenance procedures.\u003c\/p\u003e\n\u003ch3\u003eWhat is the operating temperature capability?\u003c\/h3\u003e\n\u003cp\u003eThe fluid remains effective across a wide temperature range with a freezing point of \u003cstrong\u003e-80°C\u003c\/strong\u003e and boiling point of \u003cstrong\u003e47°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eIs it compatible with aluminum, copper, and stainless steel?\u003c\/h3\u003e\n\u003cp\u003eYes. It is compatible with aluminum, copper, brass, titanium, and stainless steel (304L\/316L).\u003c\/p\u003e\n\u003ch2\u003eCall to Action\u003c\/h2\u003e\n\u003cp\u003eLooking for a reliable \u003cstrong\u003eSpecialty Fluid\u003c\/strong\u003e for immersion cooling, dielectric insulation, or industrial heat transfer applications?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Econtrol Devices today\u003c\/strong\u003e to request a quotation, download the Technical Data Sheet (TDS), obtain the Safety Data Sheet (SDS), or speak with our technical experts about selecting the right thermal management solution for your application.\u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":43837228646489,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/250530_TMC-49_Drum.webp?v=1784981570"},{"product_id":"galden®-d02","title":"GALDEN® D02 - PFPE Dielectric Fluid","description":"\u003ch1\u003e\n\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eGALDEN® D02\u003c\/span\u003e\u003cspan style=\"mso-bidi-font-size: 18.0pt; line-height: 107%; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; mso-bidi-font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003ePremium PFPE Dielectric Fluid for Electronic Reliability Testing \u0026amp; Heat Transfer\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eGALDEN® D02\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e is a high-performance \u003cb\u003especialty dielectric fluid\u003c\/b\u003e designed for electronic reliability testing, thermal management, immersion cooling, and industrial heat transfer applications. Manufactured by \u003cb\u003eTMC Industries\u003c\/b\u003e and supplied by \u003cb\u003eEcontrol Devices\u003c\/b\u003e, this PFPE (Perfluoropolyether)-based fluid offers exceptional chemical stability, outstanding dielectric performance, and excellent compatibility with sensitive electronic components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eDeveloped for demanding industrial environments, GALDEN® D02 is widely used in \u003cb\u003ethermal shock testing, hermetic seal testing, immersion cooling systems, semiconductor manufacturing, power electronics, and laboratory applications\u003c\/b\u003e. Its non-flammable, non-toxic, chemically inert formulation ensures safe and reliable operation while minimizing equipment wear and maintenance requirements. With a boiling point of \u003cb\u003e175°C\u003c\/b\u003e, extremely low pour point of \u003cb\u003e-97°C\u003c\/b\u003e, and excellent electrical insulation properties, GALDEN® D02 delivers consistent performance across a wide operating temperature range. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eKey Features\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003ePremium PFPE dielectric fluid \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eExcellent dielectric strength (40 kV) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eHigh chemical and thermal stability \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eNon-flammable and non-toxic \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eLow viscosity for efficient heat transfer \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eChemically inert and residue-free \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eExcellent oxidation resistance \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eCompatible with metals, ceramics, plastics, and elastomers \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eLow evaporation and low water absorption \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eSuitable for direct and indirect immersion cooling applications \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eBenefits\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eGALDEN® D02 helps improve the performance and reliability of critical electronic systems by providing superior thermal management and electrical insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eKey advantages include:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eExcellent heat transfer efficiency \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eReduced evaporative losses \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eImproved equipment lifespan \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eLower maintenance requirements \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eReliable performance under extreme temperatures \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eSafe operation around sensitive electronics \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eReduced operating costs \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eImproved testing accuracy during electronic reliability testing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eEnvironmentally safer than many conventional testing fluids due to its non-flammable and inert properties. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eApplications\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eGALDEN® D02 is suitable for a wide range of industrial and electronic applications, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eElectronic Reliability Testing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eThermal Shock Testing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eHermetic Seal Testing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eDirect Immersion Cooling \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eData Centers \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eSemiconductor Manufacturing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eElectronics Manufacturing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eIndustrial Heat Transfer \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eMedical Electronics \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eAerospace \u0026amp; Defense Electronics \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003ePower Supplies \u0026amp; Transformers \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eRadar Equipment \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eLaboratory Equipment \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eCooling Towers and Chillers \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"3\" cellpadding=\"0\" width=\"663\" style=\"width: 331.6pt; mso-cellspacing: 1.5pt; border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; mso-yfti-tbllook: 1184; mso-border-insideh: .5pt solid windowtext; mso-border-insidev: .5pt solid windowtext;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes; height: 14.5pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eSpecification\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eValue\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 1; height: 15.05pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eAppearance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eColorless Liquid\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2; height: 14.5pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eBoiling Point\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e175°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3; height: 15.05pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003ePour Point\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e-97°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4; height: 14.5pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eDensity @25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e1.77 g\/cm³\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5; height: 15.05pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eViscosity @25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e1.8 cSt\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6; height: 15.05pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eDielectric Strength\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e40 kV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7; height: 14.5pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eDielectric Constant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e2.1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8; height: 15.05pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eThermal Conductivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 15.05pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e0.07 W\/m°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9; mso-yfti-lastrow: yes; height: 14.5pt;\"\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eVolume Resistivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; padding: .75pt .75pt .75pt .75pt; height: 14.5pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e5 × 10¹⁵ Ohm·cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eWhy Choose GALDEN® D02?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eGALDEN® D02 is trusted worldwide for demanding electronic testing and cooling applications. Its exceptional dielectric properties, outstanding thermal stability, and excellent material compatibility make it an ideal solution for industries requiring precision cooling and reliable electrical insulation. The fluid remains stable under continuous operation, minimizes contamination, and supports long equipment life while reducing maintenance costs. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eSafety \u0026amp; Storage\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eStore GALDEN® D02 in tightly sealed, properly labeled polyethylene containers away from heat sources and combustible materials. Use appropriate personal protective equipment during handling and ensure adequate ventilation in work areas. Although the product is classified as \u003cb\u003enon-hazardous under OSHA GHS\u003c\/b\u003e, good industrial hygiene and safety practices should always be followed. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eIndustries Served\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eElectronics Manufacturing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eSemiconductor Industry \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eData Centers \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eAutomotive Electronics \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eTelecommunications \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eAerospace \u0026amp; Defense \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eIndustrial Manufacturing \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eMedical Equipment \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eResearch Laboratories \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eCall to Action\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eLooking for a premium \u003cb\u003edielectric fluid\u003c\/b\u003e, \u003cb\u003eheat transfer fluid\u003c\/b\u003e, or \u003cb\u003eelectronic testing fluid\u003c\/b\u003e?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003eContact Econtrol Devices\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: EN-IN;\"\u003e today to request pricing, download the Technical Data Sheet (TDS) or Safety Data Sheet (SDS), consult our technical experts, or place a bulk order for \u003cb\u003eGALDEN® D02\u003c\/b\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":43841125711961,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/D02pic.webp?v=1784985596"},{"product_id":"flutec™-pp1","title":"FLUTEC™ PP1","description":"\u003ch2 data-section-id=\"mu966k\" data-start=\"1368\" data-end=\"1383\"\u003eFLUTEC™ PP1 – High-Performance Electronic Cooling \u0026amp; Heat Transfer Fluid\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"96\" data-end=\"707\"\u003e\u003cstrong data-start=\"96\" data-end=\"111\"\u003eFLUTEC™ PP1\u003c\/strong\u003e is a premium \u003cstrong data-start=\"125\" data-end=\"148\"\u003eheat transfer fluid\u003c\/strong\u003e manufactured by \u003cstrong data-start=\"165\" data-end=\"183\"\u003eTMC Industries\u003c\/strong\u003e and supplied by \u003cstrong data-start=\"200\" data-end=\"220\"\u003eEcontrol Devices\u003c\/strong\u003e. Engineered for demanding industrial and electronic applications, this high-purity perfluorinated fluid delivers exceptional performance in \u003cstrong data-start=\"361\" data-end=\"382\"\u003eimmersion cooling\u003c\/strong\u003e, \u003cstrong data-start=\"384\" data-end=\"401\"\u003eheat transfer\u003c\/strong\u003e, \u003cstrong data-start=\"403\" data-end=\"425\"\u003eprecision cleaning\u003c\/strong\u003e, and \u003cstrong data-start=\"431\" data-end=\"453\"\u003egross leak testing\u003c\/strong\u003e. Its excellent thermal stability, non-flammable properties, and compatibility with a wide range of construction materials make it an ideal solution for modern cooling systems and advanced manufacturing environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mu966k\" data-start=\"1368\" data-end=\"1383\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"731\" data-end=\"849\"\u003eFLUTEC™ PP1 is designed to provide reliable performance while maintaining safety and long-term operational efficiency.\u003c\/p\u003e\n\u003cul data-start=\"851\" data-end=\"1361\"\u003e\n\u003cli data-section-id=\"2yec7m\" data-start=\"851\" data-end=\"889\"\u003eHigh-performance heat transfer fluid\u003c\/li\u003e\n\u003cli data-section-id=\"1lux41t\" data-start=\"890\" data-end=\"935\"\u003eSuitable for immersion cooling applications\u003c\/li\u003e\n\u003cli data-section-id=\"11xopjh\" data-start=\"936\" data-end=\"978\"\u003eExcellent chemical and thermal stability\u003c\/li\u003e\n\u003cli data-section-id=\"1t3o2tp\" data-start=\"979\" data-end=\"1020\"\u003eNon-flammable and practically non-toxic\u003c\/li\u003e\n\u003cli data-section-id=\"v4hce2\" data-start=\"1021\" data-end=\"1059\"\u003eOdourless and colourless formulation\u003c\/li\u003e\n\u003cli data-section-id=\"vajl7w\" data-start=\"1060\" data-end=\"1105\"\u003eCompatible with most construction materials\u003c\/li\u003e\n\u003cli data-section-id=\"1emxgck\" data-start=\"1106\" data-end=\"1153\"\u003eLow viscosity for efficient fluid circulation\u003c\/li\u003e\n\u003cli data-section-id=\"1jxzvib\" data-start=\"1154\" data-end=\"1187\"\u003eExcellent dielectric properties\u003c\/li\u003e\n\u003cli data-section-id=\"529o9l\" data-start=\"1188\" data-end=\"1217\"\u003eHigh electrical resistivity\u003c\/li\u003e\n\u003cli data-section-id=\"1ttmicm\" data-start=\"1218\" data-end=\"1361\"\u003eLong service life with indefinite shelf life when properly stored\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"1368\" data-end=\"1383\"\u003eApplications\u003c\/h2\u003e\n\u003cp data-start=\"1385\" data-end=\"1530\"\u003eFLUTEC™ PP1 is widely used across industries requiring reliable thermal management and precision cleaning. Its versatility makes it suitable for:\u003c\/p\u003e\n\u003cul data-start=\"1532\" data-end=\"1908\"\u003e\n\u003cli data-section-id=\"1j21sza\" data-start=\"1532\" data-end=\"1570\"\u003eElectronic immersion cooling systems\u003c\/li\u003e\n\u003cli data-section-id=\"12rm99u\" data-start=\"1571\" data-end=\"1599\"\u003eHeat transfer applications\u003c\/li\u003e\n\u003cli data-section-id=\"y3n0k9\" data-start=\"1600\" data-end=\"1627\"\u003eElectronics manufacturing\u003c\/li\u003e\n\u003cli data-section-id=\"1vujbfm\" data-start=\"1628\" data-end=\"1672\"\u003ePrecision cleaning of sensitive components\u003c\/li\u003e\n\u003cli data-section-id=\"qz1trb\" data-start=\"1673\" data-end=\"1693\"\u003eGross leak testing\u003c\/li\u003e\n\u003cli data-section-id=\"1m5hhjj\" data-start=\"1694\" data-end=\"1737\"\u003eCooling fluid for semiconductor equipment\u003c\/li\u003e\n\u003cli data-section-id=\"ruywq7\" data-start=\"1738\" data-end=\"1771\"\u003eSolvent for fluorinated greases\u003c\/li\u003e\n\u003cli data-section-id=\"1tsqj2v\" data-start=\"1772\" data-end=\"1824\"\u003eOrganic Rankine Engine (ORC) heat transfer systems\u003c\/li\u003e\n\u003cli data-section-id=\"ew92j4\" data-start=\"1825\" data-end=\"1908\"\u003eHigh-performance industrial cooling systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"b5ogp3\" data-start=\"1915\" data-end=\"1946\"\u003eSuperior Cooling Performance\u003c\/h2\u003e\n\u003cp data-start=\"1948\" data-end=\"2444\"\u003eFLUTEC™ PP1 has been developed to deliver outstanding cooling efficiency for electronic and industrial systems. With a \u003cstrong data-start=\"2067\" data-end=\"2092\"\u003eboiling point of 57°C\u003c\/strong\u003e, \u003cstrong data-start=\"2094\" data-end=\"2135\"\u003elow kinematic viscosity of 0.39 mm²\/s\u003c\/strong\u003e, and excellent thermal conductivity, the fluid rapidly removes heat from critical components while maintaining stable operating temperatures. Its high dielectric strength allows electronic equipment to operate safely in immersion cooling environments, helping reduce thermal stress and extend equipment life.\u003c\/p\u003e\n\u003cp data-start=\"2446\" data-end=\"2671\"\u003eThe fluid is widely used as a replacement for legacy electronic cooling fluids in heat transfer and immersion cooling applications where reliability and long-term stability are essential.\u003c\/p\u003e\n\u003ch2 data-section-id=\"gs67k0\" data-start=\"2678\" data-end=\"2703\"\u003eMaterial Compatibility\u003c\/h2\u003e\n\u003cp data-start=\"2705\" data-end=\"3032\"\u003eOne of the major advantages of FLUTEC™ PP1 is its broad compatibility with construction materials commonly used in industrial equipment and electronic cooling systems. The chemically inert formulation minimizes the risk of corrosion or material degradation, making it suitable for long-term operation in demanding environments.\u003c\/p\u003e\n\u003cp data-start=\"3034\" data-end=\"3218\"\u003eIts non-reactive nature also helps reduce maintenance requirements while ensuring consistent cooling performance throughout the product lifecycle.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1k51nc3\" data-start=\"3225\" data-end=\"3259\"\u003eSafety \u0026amp; Environmental Benefits\u003c\/h2\u003e\n\u003cp data-start=\"3261\" data-end=\"3552\"\u003eFLUTEC™ PP1 is designed with both safety and operational reliability in mind. The fluid is \u003cstrong data-start=\"3352\" data-end=\"3369\"\u003enon-flammable\u003c\/strong\u003e, practically non-toxic, chemically inert, and can be safely handled using standard laboratory practices. It has an indefinite shelf life when stored in its original sealed container.\u003c\/p\u003e\n\u003cp data-start=\"3554\" data-end=\"4021\"\u003eAlthough FLUTEC™ PP1 is classified within the PFAS family based on current regulatory definitions, it \u003cstrong data-start=\"3656\" data-end=\"3768\"\u003edoes not exhibit the toxic or bioaccumulative characteristics associated with many functional PFAS materials\u003c\/strong\u003e. The product is also registered under TSCA regulations and does not meet the EPA definition of a volatile organic compound (VOC), making it suitable for many industrial applications requiring regulatory compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1poq2a9\" data-start=\"4028\" data-end=\"4050\"\u003ePhysical Properties\u003c\/h2\u003e\n\u003cp data-start=\"4052\" data-end=\"4157\"\u003eFLUTEC™ PP1 offers excellent physical characteristics that support high-performance cooling applications:\u003c\/p\u003e\n\u003cul data-start=\"4159\" data-end=\"4482\"\u003e\n\u003cli data-section-id=\"51m7gn\" data-start=\"4159\" data-end=\"4184\"\u003eBoiling Point: \u003cstrong data-start=\"4176\" data-end=\"4184\"\u003e57°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tifvm9\" data-start=\"4185\" data-end=\"4208\"\u003ePour Point: \u003cstrong data-start=\"4199\" data-end=\"4208\"\u003e-90°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qg0qro\" data-start=\"4209\" data-end=\"4234\"\u003eDensity: \u003cstrong data-start=\"4220\" data-end=\"4234\"\u003e1.718 kg\/L\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13ibsvc\" data-start=\"4235\" data-end=\"4262\"\u003eMolecular Weight: \u003cstrong data-start=\"4255\" data-end=\"4262\"\u003e338\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ug9e4j\" data-start=\"4263\" data-end=\"4299\"\u003eDynamic Viscosity: \u003cstrong data-start=\"4284\" data-end=\"4299\"\u003e0.656 mPa·s\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vna375\" data-start=\"4300\" data-end=\"4351\"\u003eHigh Dielectric Breakdown Strength: \u003cstrong data-start=\"4338\" data-end=\"4351\"\u003e\u0026gt;16 kV\/mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hk0l4b\" data-start=\"4352\" data-end=\"4394\"\u003eElectrical Resistivity: \u003cstrong data-start=\"4378\" data-end=\"4394\"\u003e\u0026gt;10¹³ ohm·cm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l6fwo1\" data-start=\"4395\" data-end=\"4482\"\u003eLow Surface Tension for efficient heat transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"15ptd9b\" data-start=\"4489\" data-end=\"4515\"\u003eWhy Choose FLUTEC™ PP1?\u003c\/h2\u003e\n\u003cp data-start=\"4517\" data-end=\"5196\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eIf you're looking for a \u003cstrong data-start=\"4541\" data-end=\"4581\"\u003ehigh-performance heat transfer fluid\u003c\/strong\u003e for immersion cooling, electronics manufacturing, precision cleaning, or industrial thermal management, \u003cstrong data-start=\"4686\" data-end=\"4701\"\u003eFLUTEC™ PP1\u003c\/strong\u003e is an excellent choice. Manufactured by \u003cstrong data-start=\"4742\" data-end=\"4760\"\u003eTMC Industries\u003c\/strong\u003e and supplied by \u003cstrong data-start=\"4777\" data-end=\"4797\"\u003eEcontrol Devices\u003c\/strong\u003e, it combines superior thermal performance, exceptional material compatibility, excellent dielectric properties, and long-term chemical stability. Whether used in semiconductor manufacturing, electronics production, laboratory testing, or industrial cooling systems, FLUTEC™ PP1 delivers reliable performance, reduced maintenance, and dependable cooling efficiency for mission-critical applications.\u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":44193567375449,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/Flutec_PP1_Brown_Jug.webp?v=1785245370"},{"product_id":"galden®-d02-ts","title":"GALDEN® D02 TS","description":"\u003ch2\u003e\u003cspan style=\"font-size: 24.0pt; mso-font-kerning: 18.0pt;\"\u003eGALDEN® D02 TS – High-Performance PFPE Electronic Reliability Testing Fluid\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003e\u003cb\u003eGALDEN® D02 TS\u003c\/b\u003e is a premium \u003cb\u003ePFPE (Perfluoropolyether) electronic reliability testing fluid\u003c\/b\u003e manufactured by \u003cb\u003eTMC Industries\u003c\/b\u003e and supplied by \u003cb\u003eEcontrol Devices\u003c\/b\u003e. Designed for advanced electronics manufacturing and thermal management, this high-performance fluorinated fluid is specifically developed for \u003cb\u003eelectronic reliability testing\u003c\/b\u003e, \u003cb\u003ethermal shock testing\u003c\/b\u003e, \u003cb\u003eimmersion cooling\u003c\/b\u003e, and \u003cb\u003eheat transfer applications\u003c\/b\u003e. Its exceptional chemical stability, excellent dielectric properties, and non-flammable formulation make it an ideal solution for industries requiring reliable thermal performance and long-term equipment protection.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eGALDEN® D02 TS is widely used in semiconductor manufacturing, aerospace, electronics testing laboratories, and industrial cooling systems where precision, safety, and performance are critical.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; line-height: 107%;\"\u003eKey Features\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eGALDEN® D02 TS delivers outstanding performance across demanding industrial applications through its advanced PFPE formulation.\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eHigh-performance PFPE heat transfer fluid\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for electronic reliability and thermal shock testing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eExcellent dielectric insulation properties\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eNon-flammable and non-toxic formulation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eChemically inert and highly stable\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eOutstanding oxidation and thermal degradation resistance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLow viscosity for efficient heat transfer\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLow water absorption\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompatible with metals, ceramics, plastics, and elastomers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnvironmentally safer alternative for critical cooling applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; line-height: 107%;\"\u003eApplications\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eGALDEN® D02 TS is engineered for industries requiring precise temperature control and reliable electronic cooling.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eTypical applications include:\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eElectronic reliability testing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eThermal shock testing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eHeat transfer systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eDirect immersion cooling\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eIndirect liquid cooling\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eSemiconductor manufacturing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eWafer etching and ion implantation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eRadar and defense electronics\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eTransformers and power supplies\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eIndustrial chillers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eCooling towers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eFreeze dryers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\"\u003eLaboratory testing equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eIts versatility makes it suitable for both research laboratories and large-scale industrial manufacturing facilities\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; line-height: 107%;\"\u003eSuperior Heat Transfer Performance\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eGALDEN® D02 TS is formulated to deliver exceptional thermal management while maintaining outstanding electrical insulation. The fluid efficiently transfers heat away from electronic components, helping improve equipment reliability and extend operational life.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eWith a \u003cb\u003enormal boiling point of 165°C\u003c\/b\u003e, \u003cb\u003elow pour point of -97°C\u003c\/b\u003e, \u003cb\u003ethermal conductivity of 0.07 W\/m·K\u003c\/b\u003e, and \u003cb\u003eexcellent dielectric strength of 40 kV\u003c\/b\u003e, GALDEN® D02 TS performs consistently across a wide operating temperature range. Its low surface tension allows the fluid to reach complex electronic assemblies, ensuring efficient cooling even in hard-to-access areas.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eThe fluid also exhibits low kinematic viscosity, allowing smooth circulation with reduced pumping requirements while maintaining excellent cooling efficiency.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; line-height: 107%;\"\u003eMaterial Compatibility\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eGALDEN® D02 TS is highly compatible with a wide range of industrial materials, making it an ideal choice for existing cooling and testing systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eCompatible materials include:\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eStainless Steel\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eAluminum\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eCopper\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eCeramics\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eGlass\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eEngineering Plastics\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eElastomers\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\"\u003eComposite Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eIts chemically inert nature minimizes corrosion, oxidation, and material degradation, ensuring long service life for both the fluid and cooling equipment.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; line-height: 107%;\"\u003eSafety \u0026amp; Environmental Benefits\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eSafety and reliability are key advantages of GALDEN® D02 TS. The fluid is \u003cb\u003enon-flammable\u003c\/b\u003e, \u003cb\u003enon-toxic\u003c\/b\u003e, and chemically inert, making it safer to handle than many conventional heat transfer fluids.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eIts PFPE chemistry provides excellent resistance to oxidation and thermal degradation, ensuring stable performance even during continuous high-temperature operation. Because it contains no hydrogen in its molecular structure, the fluid also exhibits extremely low water absorption, helping maintain consistent dielectric performance over extended service periods.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eIts environmentally responsible formulation supports industries seeking safer and more reliable thermal management solutions without compromising performance.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; line-height: 107%;\"\u003eTechnical Highlights\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eGALDEN® D02 TS offers excellent physical and electrical characteristics for demanding industrial applications:\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eBoiling Point:\u003c\/b\u003e 165°C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003ePour Point:\u003c\/b\u003e -97°C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eDensity (25°C):\u003c\/b\u003e 1.77 g\/cm³\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eKinematic Viscosity (25°C):\u003c\/b\u003e 17 cSt\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eThermal Conductivity:\u003c\/b\u003e 0.07 W\/m·K\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eDielectric Strength:\u003c\/b\u003e 40 kV (2.54 mm gap)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eDielectric Constant:\u003c\/b\u003e 2.1\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eVolume Resistivity:\u003c\/b\u003e 5×10¹⁵ Ohm·cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eThese properties make GALDEN® D02 TS an excellent choice for precision cooling, electronic testing, and industrial heat transfer applications.\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; line-height: 107%;\"\u003eWhy Choose GALDEN® D02 TS?\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eIf you're searching for a \u003cb\u003ehigh-performance PFPE heat transfer fluid\u003c\/b\u003e, \u003cb\u003eelectronic reliability testing fluid\u003c\/b\u003e, or \u003cb\u003eimmersion cooling fluid\u003c\/b\u003e, \u003cb\u003eGALDEN® D02 TS\u003c\/b\u003e is an excellent solution. Manufactured by \u003cb\u003eTMC Industries\u003c\/b\u003e and supplied by \u003cb\u003eEcontrol Devices\u003c\/b\u003e, it delivers superior thermal stability, exceptional dielectric insulation, excellent material compatibility, and long-term chemical reliability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003eWhether you're involved in semiconductor manufacturing, electronics testing, aerospace applications, or industrial thermal management, GALDEN® D02 TS provides the performance, safety, and efficiency needed to keep mission-critical systems operating at their best while reducing maintenance and improving equipment reliability.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto;\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":44249280315481,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/s.jpg?v=1785329544"},{"product_id":"tmc-649-engineered-fluid","title":"TMC-649 ENGINEERED FLUID","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eTMC-649 Engineered Fluid from \u003cstrong\u003eTMC Industries\u003c\/strong\u003e, supplied by \u003cstrong\u003eEcontrol Devices\u003c\/strong\u003e, is a high-performance engineered fluid designed as a direct replacement for and fully miscible with \u003cstrong\u003e3M™ Novec™ 649\u003c\/strong\u003e. It is a clear, colorless, low-odor fluid developed to replace ozone-depleting substances (ODSs) and compounds with high global warming potential (GWP), including sulfur hexafluoride (SF6), HFC-134a, and HFC-245fa. The fluid is formulated to deliver a balance of physical, thermal, and electrical properties while maintaining desirable environmental characteristics, making it suitable for a wide range of industrial heat transfer applications. \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTMC-649 Engineered Fluid is a chemically identical replacement for \u003cstrong\u003e3M™ Novec™ 649\u003c\/strong\u003e and is specifically developed for heat transfer applications where non-flammability and environmental performance are important considerations. It is suitable for use in electronics cooling (dual phase), computer and data center cooling, power electronics such as IGBTs and inverters, solar applications, transformers, and other heat transfer equipment. These application areas make TMC-649 a practical solution for industries that require dependable thermal management while maintaining environmental responsibility.\u003c\/p\u003e\n\u003cp\u003eThe fluid offers several key features that support its performance across demanding industrial environments. TMC-649 provides a \u003cstrong\u003eLow Global Warming Potential (GWP)\u003c\/strong\u003e, \u003cstrong\u003eZero Ozone Depletion Potential (ODP)\u003c\/strong\u003e, an \u003cstrong\u003eExcellent Environmental Profile\u003c\/strong\u003e, and is \u003cstrong\u003eNoncorrosive\u003c\/strong\u003e. These characteristics contribute to its suitability for applications where reliable performance and environmental considerations are equally important.\u003c\/p\u003e\n\u003cp\u003eTMC-649 is designed to remain stable during operation. It should be used in a sealed system to prevent interaction with water. In the absence of water, the fluid remains remarkably stable at temperatures exceeding \u003cstrong\u003e300°C\u003c\/strong\u003e, making it suitable for demanding thermal applications requiring long-term operational stability.\u003c\/p\u003e\n\u003cp\u003eThe physical and environmental properties of TMC-649 further support its performance. It has a \u003cstrong\u003eboiling point of 49°C (120°F)\u003c\/strong\u003e, a \u003cstrong\u003efreeze\/pour point of -108°C (-162.4°F)\u003c\/strong\u003e, an \u003cstrong\u003eaverage molecular weight of 316.04 g\/mol\u003c\/strong\u003e, \u003cstrong\u003eliquid density of 1.60 g\/mL\u003c\/strong\u003e, \u003cstrong\u003ekinematic viscosity of 0.64 cPs\u003c\/strong\u003e, \u003cstrong\u003especific heat of 1103 J\/kg-K\u003c\/strong\u003e, \u003cstrong\u003edielectric strength of 48 kV\u003c\/strong\u003e, \u003cstrong\u003edielectric constant of 1.8 at 1 kHz\u003c\/strong\u003e, and \u003cstrong\u003eno flash point\u003c\/strong\u003e. The fluid also has \u003cstrong\u003eZero Ozone Depletion Potential (ODP)\u003c\/strong\u003e and a \u003cstrong\u003eGlobal Warming Potential (GWP) of 1\u003c\/strong\u003e, offering an environmentally responsible solution for heat transfer applications.\u003c\/p\u003e\n\u003cp\u003eMaterial compatibility testing shows that TMC-649 has good compatibility with rubber, metal, and a variety of other materials while producing minimal impact during use. Experimental evaluations indicate compatibility with materials including EPDM, Silicone Rubber, Neoprene, PTFE (Teflon 1705), Nitrile, HDPE, Polyamide Nylon 6xt, PVC, Viton, and Polyurethane (PU), making the fluid suitable for use in systems containing a wide range of commonly used engineering materials.\u003c\/p\u003e\n\u003cp\u003eTMC-649 Engineered Fluid is available in multiple packaging options, including \u003cstrong\u003e1 Gallon Jug (12 lb \/ 5.4 kg), 5 Gallon Pail (44 lb \/ 20 kg), 55 Gallon Drum (550 lb \/ 250 kg), Sample (2.2 lb \/ 1 kg), and 275 Gallon Tote available upon request\u003c\/strong\u003e. The product has a \u003cstrong\u003e5-year shelf life\u003c\/strong\u003e when stored in its original packaging under normal storage conditions. TMC Industries also offers material re-certification every five years for up to \u003cstrong\u003e20 years\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor sustainability, TMC-649 can be recycled and reused through the TMC Industries reclamation program. Used fluorinated fluids can be restored to like-new condition, tested to meet new product specifications, and supplied with a Certificate of Analysis. The reclamation program is backed by a \u003cstrong\u003e100% satisfaction guarantee\u003c\/strong\u003e on reclaimed fluids.\u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":44257313292377,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/TMC-649_Brown_Jug.webp?v=1785420529"},{"product_id":"krytox-1514-vacuum-pump-fluid","title":"KRYTOX 1514 Vacuum Pump Fluid","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKRYTOX 1514 Vacuum Pump Fluid by TMC Industries\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKRYTOX 1514 Vacuum Pump Fluid\u003c\/strong\u003e from \u003cstrong\u003eTMC Industries\u003c\/strong\u003e, supplied by \u003cstrong\u003eEcontrol Devices\u003c\/strong\u003e, is designed for applications where conventional vacuum pump oils create safety, waste disposal, and maintenance challenges. This vacuum pump fluid is nonflammable, helping eliminate the chance of fire in pumps, and is non-reactive, making it safe for use in oxygen systems. It can replace competitive PFPE fluids as well as other types of vacuum pump fluids used in industrial applications. Krytox fluids do not contain acetal groups that are susceptible to attack by Lewis acids, providing superior stability as a vacuum pump fluid. They are precisely distilled to deliver low vapor pressures and superior performance while also being recyclable.\u003c\/p\u003e\n\u003cp\u003eKRYTOX 1514 Vacuum Pump Fluid is suitable for applications where low vapor pressure and reliable operation are essential. Its precisely distilled formulation supports high-performance vacuum pump operation and is intended for demanding industrial environments. The product is also recyclable, helping support fluid recovery and reuse programs.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eKRYTOX 1514 Vacuum Pump Fluid is recommended for a variety of industrial applications, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVacuum pumps\u003c\/li\u003e\n\u003cli\u003ePlasma and CVD operations\u003c\/li\u003e\n\u003cli\u003eSemiconductor manufacturing environments where process chemicals can attack conventional lubricants\u003c\/li\u003e\n\u003cli\u003eVacuum system valves, seals, bearings, and connectors where low vapor pressure, low outgassing, and contamination control are important\u003c\/li\u003e\n\u003cli\u003eEdwards Root blowers EH250–EH4200, QMB Series, and HV Series\u003c\/li\u003e\n\u003cli\u003eReplacement for Fomblin 14\/6, Leybold HE1600, Halocarbon 56, and Castrol Braycote 1723\/1723+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cp\u003eKRYTOX 1514 Vacuum Pump Fluid offers several important performance characteristics, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNonflammable formulation that eliminates the chance of fire in pumps.\u003c\/li\u003e\n\u003cli\u003eNon-reactive and safe for use in oxygen systems.\u003c\/li\u003e\n\u003cli\u003eCan replace competitive PFPE fluids and other vacuum pump fluids.\u003c\/li\u003e\n\u003cli\u003eDoes not contain acetal groups susceptible to Lewis acid attack.\u003c\/li\u003e\n\u003cli\u003eSuperior stability as a vacuum pump fluid.\u003c\/li\u003e\n\u003cli\u003ePrecisely distilled to provide low vapor pressure.\u003c\/li\u003e\n\u003cli\u003eRecyclable for reuse after reclamation.\u003c\/li\u003e\n\u003cli\u003eProvides superior performance in demanding vacuum applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMaterial Compatibility\u003c\/h2\u003e\n\u003cp\u003eKRYTOX VPF fluids are inert and non-reactive to elastomers, plastics, and metals. Initial testing has shown no problems with Teflon™ fluoroplastic resin, Kalrez® perfluoroelastomer parts, Viton™ fluoroelastomer, nitrile, and silicone rubbers. The performance of soluble additives may degrade at temperatures above \u003cstrong\u003e182°C (360°F)\u003c\/strong\u003e over long periods.\u003c\/p\u003e\n\u003ch2\u003eProduct Properties\u003c\/h2\u003e\n\u003cp\u003eKRYTOX 1514 Vacuum Pump Fluid has the following typical properties:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKinematic Viscosity @ 20°C: \u003cstrong\u003e140 cSt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eKinematic Viscosity @ 100°C: \u003cstrong\u003e7.2 cSt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDensity @ 20°C: \u003cstrong\u003e1.89 g\/cc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDensity @ 100°C: \u003cstrong\u003e1.74 g\/cc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePour Point: \u003cstrong\u003e–54°C (–65°F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood Contact Approval: \u003cstrong\u003eNSF H-1 \/ No\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDisposal and Recycling\u003c\/h2\u003e\n\u003cp\u003eKRYTOX 1514 Vacuum Pump Fluid can be reclaimed and reused. TMC Industries provides reclamation services that restore used fluorinated fluids and oils to like-new condition. The reclaimed fluids are tested to meet new product specifications, supplied clear and odorless, and include a Certificate of Analysis with every order. TMC Industries also backs its reclaimed fluids with a \u003cstrong\u003e100% satisfaction guarantee\u003c\/strong\u003e and a no-questions-asked refund policy.\u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":44260591730777,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/KRYTOX1514VACUUMPUMPFLUID4.webp?v=1785492720"},{"product_id":"krytox-1506-vacuum-pump-fluid","title":"KRYTOX 1506 VACUUM PUMP FLUID","description":"\u003cdiv class=\"text-base my-auto mx-auto [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eKRYTOX 1506 Vacuum Pump Fluid by TMC Industries\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKRYTOX 1506 Vacuum Pump Fluid\u003c\/strong\u003e from \u003cstrong\u003eTMC Industries\u003c\/strong\u003e, supplied by \u003cstrong\u003eEcontrol Devices\u003c\/strong\u003e, is developed for applications where conventional vacuum pump oils create safety, waste disposal, and maintenance concerns. This vacuum pump fluid is nonflammable, eliminating the chance of fire in pumps, and is non-reactive, making it safe for use in oxygen systems. It can replace competitive PFPE fluids as well as other types of vacuum pump fluids used in industrial applications. Unlike many conventional fluids, Krytox vacuum pump fluids do not contain acetal groups that are susceptible to attack by Lewis acids, providing superior stability in demanding vacuum environments. The fluid is precisely distilled to deliver low vapor pressure and reliable performance while also being recyclable.\u003c\/p\u003e\n\u003cp\u003eKRYTOX 1506 Vacuum Pump Fluid is designed for applications requiring dependable performance and low vapor pressure. The product supports industrial vacuum systems where contamination control and operational reliability are important. Its recyclable formulation allows used fluid to be reclaimed and reused, supporting efficient maintenance practices.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eKRYTOX 1506 Vacuum Pump Fluid is recommended for a wide range of industrial vacuum applications, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVacuum pumps\u003c\/li\u003e\n\u003cli\u003ePlasma processing\u003c\/li\u003e\n\u003cli\u003eChemical Vapor Deposition (CVD) operations\u003c\/li\u003e\n\u003cli\u003eSemiconductor manufacturing environments where process chemicals can attack conventional lubricants\u003c\/li\u003e\n\u003cli\u003eVacuum system valves, seals, bearings, and connectors requiring low vapor pressure, low outgassing, and contamination tolerance\u003c\/li\u003e\n\u003cli\u003eEdwards Root blowers EH250–EH4200, QMB Series, and HV Series\u003c\/li\u003e\n\u003cli\u003eReplacement for Fomblin 14\/6, Leybold HE1600, Halocarbon 56, and Castrol Braycote 1723\/1723+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications – KRYTOX 1506 Vacuum Pump Fluid\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProperty\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTest Method \/ Condition\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth align=\"right\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Molecular Weight\u003c\/td\u003e\n\u003ctd\u003eNMR\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVapor Pressure @ 20°C (68°F)\u003c\/td\u003e\n\u003ctd\u003eKnudsen\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4 × 10⁻⁷ torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVapor Pressure @ 50°C (122°F)\u003c\/td\u003e\n\u003ctd\u003eKnudsen\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 × 10⁻⁵ torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVapor Pressure @ 100°C (212°F)\u003c\/td\u003e\n\u003ctd\u003eKnudsen\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 × 10⁻³ torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVapor Pressure @ 200°C (392°F)\u003c\/td\u003e\n\u003ctd\u003eKnudsen\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 × 10⁻¹ torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKinematic Viscosity @ 20°C (68°F)\u003c\/td\u003e\n\u003ctd\u003eASTM D445\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e60 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKinematic Viscosity @ 50°C (122°F)\u003c\/td\u003e\n\u003ctd\u003eASTM D445\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15.5 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKinematic Viscosity @ 100°C (212°F)\u003c\/td\u003e\n\u003ctd\u003eASTM D445\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4.1 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDensity @ 20°C (68°F)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.88 g\/cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDensity @ 50°C (122°F)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.82 g\/cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDensity @ 100°C (212°F)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.73 g\/cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDensity @ 200°C (392°F)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.54 g\/cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePour Point\u003c\/td\u003e\n\u003ctd\u003eASTM D97\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e–60°C (–76°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistillation (10%) @ 0.4 torr\u003c\/td\u003e\n\u003ctd\u003eASTM D1160\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e160°C (320°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistillation (90%) @ 0.4 torr\u003c\/td\u003e\n\u003ctd\u003eASTM D1160\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e220°C (428°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat of Vaporization\u003c\/td\u003e\n\u003ctd\u003eKnudsen (150–250°C)\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e9 cal\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolatility (22 hr @ 121°C \/ 250°F)\u003c\/td\u003e\n\u003ctd\u003eASTM D2595\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e6.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Tension @ 25°C (77°F)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e17 dyn\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood Contact Approval\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNSF H-1 \/ No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cp\u003eKRYTOX 1506 Vacuum Pump Fluid offers the following features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNonflammable formulation.\u003c\/li\u003e\n\u003cli\u003eEliminates the chance of fire in pumps.\u003c\/li\u003e\n\u003cli\u003eNon-reactive and safe for oxygen systems.\u003c\/li\u003e\n\u003cli\u003eCompatible as a replacement for competitive PFPE fluids and other vacuum pump fluids.\u003c\/li\u003e\n\u003cli\u003eDoes not contain acetal groups susceptible to Lewis acid attack.\u003c\/li\u003e\n\u003cli\u003eSuperior stability for vacuum pump applications.\u003c\/li\u003e\n\u003cli\u003ePrecisely distilled to provide low vapor pressure.\u003c\/li\u003e\n\u003cli\u003eRecyclable for fluid recovery and reuse.\u003c\/li\u003e\n\u003cli\u003eDesigned to provide superior performance in demanding vacuum applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMaterial Compatibility\u003c\/h2\u003e\n\u003cp\u003eKRYTOX vacuum pump fluids are inert and non-reactive with elastomers, plastics, and metals. Initial testing has shown compatibility with Teflon™ fluoroplastic resin, Kalrez® perfluoroelastomer parts, Viton™ fluoroelastomer, nitrile, and silicone rubbers. For Krytox XP products, the performance of soluble additives may degrade after long-term exposure to temperatures above \u003cstrong\u003e182°C (360°F)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eProduct Properties\u003c\/h2\u003e\n\u003cp\u003eTypical properties of KRYTOX 1506 Vacuum Pump Fluid include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKinematic Viscosity @ 20°C: \u003cstrong\u003e60 cSt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eKinematic Viscosity @ 50°C: \u003cstrong\u003e15.5 cSt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eKinematic Viscosity @ 100°C: \u003cstrong\u003e4.1 cSt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDensity @ 20°C: \u003cstrong\u003e1.88 g\/cc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDensity @ 100°C: \u003cstrong\u003e1.73 g\/cc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePour Point: \u003cstrong\u003e–60°C (–76°F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFood Contact Approval: \u003cstrong\u003eNSF H-1 \/ No\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDisposal and Recycling\u003c\/h2\u003e\n\u003cp\u003eKRYTOX 1506 Vacuum Pump Fluid is recyclable and can be reclaimed for reuse. TMC Industries provides reclamation services that restore used fluorinated fluids and oils to like-new condition. Reclaimed fluids are tested to meet new product specifications and are supplied with a Certificate of Analysis. TMC Industries also offers a \u003cstrong\u003e100% satisfaction guarantee\u003c\/strong\u003e on reclaimed fluids and supports customers with a no-questions-asked refund policy. This helps extend fluid life while supporting environmentally responsible fluid management.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":44260614864985,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}]}],"url":"https:\/\/econtroldevices.com\/collections\/low-temperature-fluids.oembed","provider":"Econtroldevices","version":"1.0","type":"link"}