{"title":"Phase sequence relay","description":"\u003ch1\u003ePhase Sequence Relay\u003c\/h1\u003e\n\u003cp\u003eA phase sequence relay is an electrical device designed to monitor the sequence of phases in a three-phase power system. It protects equipment from damage caused by incorrect phase rotation. Econtrol Device specializes in Phase Sequence Relay distribution, ensuring seamless power management. With precision engineering and reliability, they provide solutions vital for safeguarding electrical systems, optimizing performance, and preventing damage from phase imbalances.\u003c\/p\u003e","products":[{"product_id":"gic-mg73bh-voltage-monitoring-relay","title":"GIC MG73BH Voltage Monitoring Relay","description":"\u003ch3\u003e\u003cstrong\u003eGIC MG73BH Voltage Monitoring Relay\u003c\/strong\u003e\u003c\/h3\u003e\nThe \u003cstrong\u003eGIC MG73BH\u003c\/strong\u003e is a \u003cstrong\u003evoltage monitoring relay\u003c\/strong\u003e used to protect electrical equipment from unsafe voltage levels. It helps detect issues like over-voltage, under-voltage, phase failure, and wrong phase sequence. This relay is ideal for use in control panels and industrial machines.\n\u003ch3\u003e\u003cstrong\u003eTechnical Information:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e MG73BH\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 3-phase, 415V AC (±30%)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRelay Output:\u003c\/strong\u003e 1 changeover contact (SPDT), 5A at 250V AC\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Over-voltage, under-voltage, phase loss, phase reversal\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdjustable Settings:\u003c\/strong\u003e Voltage limits and time delay\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Status and fault indication\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e Compact design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e Key Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eDetects phase failure and wrong phase order\u003c\/li\u003e\n \t\u003cli\u003eMonitors both high and low voltage\u003c\/li\u003e\n \t\u003cli\u003eAdjustable voltage range and delay time\u003c\/li\u003e\n \t\u003cli\u003eDIN rail mount for easy setup\u003c\/li\u003e\n \t\u003cli\u003eLED status indicators for clear display\u003c\/li\u003e\n \t\u003cli\u003eCompact and durable design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eBenefits of \u003c\/strong\u003e\u003cstrong\u003eVoltage Monitoring Relay\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eProtects machines and equipment from voltage problems\u003c\/li\u003e\n \t\u003cli\u003ePrevents damage due to wrong phase connection\u003c\/li\u003e\n \t\u003cli\u003eHelps avoid downtime and maintenance costs\u003c\/li\u003e\n \t\u003cli\u003eEasy to install and configure\u003c\/li\u003e\n \t\u003cli\u003eLong-lasting and reliable performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplications of \u003c\/strong\u003e\u003cstrong\u003eVoltage Monitoring Relay\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eIndustrial control panels\u003c\/li\u003e\n \t\u003cli\u003eMotor and pump protection\u003c\/li\u003e\n \t\u003cli\u003eCommercial buildings\u003c\/li\u003e\n \t\u003cli\u003ePower distribution boards\u003c\/li\u003e\n \t\u003cli\u003eHVAC systems\u003c\/li\u003e\n \t\u003cli\u003eGenerator control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e How to Use\u003c\/strong\u003e\u003c\/h3\u003e\nTo use the \u003cstrong\u003eGIC MG73BH Voltage Monitoring Relay\u003c\/strong\u003e, mount it on a DIN rail inside the electrical control panel. Connect it to the 3-phase power supply and set the voltage limits and delay time using the adjustable knobs. The relay constantly checks for voltage issues like phase loss, wrong phase order, and over or under voltage. If it detects any fault, the relay will switch its output to protect your system. The LED lights make it easy to see the working and fault status.\n\u003ch3\u003e\u003cstrong\u003e Why You Should Buy:\u003c\/strong\u003e\u003c\/h3\u003e\nIf you want to protect your equipment from voltage issues, the \u003cstrong\u003eGIC MG73BH\u003c\/strong\u003e is a great choice. It’s simple to install, easy to set, and helps prevent costly breakdowns and electrical failures.\n\u003ch4\u003e\u003cstrong\u003e Where and Who Uses It:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWhere:\u003c\/strong\u003e Electrical panels, factories, buildings, and generator setups\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWho:\u003c\/strong\u003e Electricians, automation engineers, maintenance teams, and OEMs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e About the Manufacturer:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cstrong\u003eGIC India\u003c\/strong\u003e is a leading company that makes electrical control and protection devices. Their products, like timers, relays, and monitoring systems, are used in industries across the world. GIC is known for making quality products that are easy to use and built to last.","brand":"Voltage Monitoring Series","offers":[{"title":"Default Title","offer_id":43327744442457,"sku":"ECDTMR0007","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/Untitled-design-1-8.png?v=1779108951"},{"product_id":"gic-md21df-voltage-monitoring-relay-sm-175-208-480-vac-3-phase-5amps","title":"GIC MD21DF Voltage Monitoring Relay SM 175 208-480 VAC 3 Phase 5Amps","description":"\u003ch3\u003e\u003cstrong\u003eGIC MD21DF Voltage Monitoring Relay\u003c\/strong\u003e\u003c\/h3\u003e\nThe \u003cstrong\u003eGIC MD21DF\u003c\/strong\u003e is a compact and reliable \u003cstrong\u003evoltage monitoring relay\u003c\/strong\u003e designed to protect electrical systems from voltage fluctuations and phase failures. It supports 3-phase voltage input and offers fault detection like over-voltage, under-voltage, phase loss, and phase sequence errors. It is widely used in control panels and industrial equipment for \u003cstrong\u003epower safety and system stability\u003c\/strong\u003e.\n\u003ch3\u003e\u003cstrong\u003eMD21DF – Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSupply Voltage (±6%)\u003c\/strong\u003e: 208 - 480 VAC (3 Phase 3 Wire)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSupply Variation\u003c\/strong\u003e: -12% to +10% (of rated supply)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower Consumption (Max.)\u003c\/strong\u003e: 3.5 VA\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSettable Nominal Voltage\u003c\/strong\u003e: 208 - 220 - 380 - 400 - 415 - 440 - 480 VAC\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePhase Loss\u003c\/strong\u003e: Yes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePhase Sequence\u003c\/strong\u003e: Yes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTrip Levels\u003c\/strong\u003e:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePhase Asymmetry\u003c\/strong\u003e: N\/A\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUnder Voltage\u003c\/strong\u003e: -20% to -20% (of rated supply)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOver Voltage\u003c\/strong\u003e: +2% to +20% (of rated supply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTime Delay\u003c\/strong\u003e:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOn Delay\u003c\/strong\u003e: 5 s\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTrip Time (OFF Delay)\u003c\/strong\u003e: 0.5 to 15 s (Selectable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRelay Output\u003c\/strong\u003e: 1 C\/O\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eContact Rating\u003c\/strong\u003e: 5A @ 250 VAC \/ 30 VDC (Resistive)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eElectrical Life\u003c\/strong\u003e: 1×10⁵\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMechanical Life\u003c\/strong\u003e: 3×10⁶\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUtilization Category\u003c\/strong\u003e:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAC - 15\u003c\/strong\u003e: Rated Voltage (Ue): 120\/240 V, Rated Current (Ie): 3.0\/1.5 A\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDC - 13\u003c\/strong\u003e: Rated Voltage (Ue): 24\/125\/250 V, Rated Current (Ie): 0.20\/0.22\/0.1 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLED Indication\u003c\/strong\u003e:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHealthy\u003c\/strong\u003e: Red LED: Supply Healthy → Continuous ON, Phase Reverse → Flashing\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUV\u003c\/strong\u003e: Red LED: Under Voltage → Continuous ON\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOV\u003c\/strong\u003e: Red LED: Over Voltage → Continuous ON\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAsymmetry\u003c\/strong\u003e: Red LED: Asymmetry → Continuous ON\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAll LEDs\u003c\/strong\u003e: Phase Fail or Higher Cut OFF (\u0026gt;560 VAC) or lower cut off (\u0026lt;175 VAC). Blinking → Pot changed during running conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -15°C to +60°C\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -20°C to +80°C\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHumidity (Non-Condensing)\u003c\/strong\u003e: 95% (Rh)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Flame Retardant UL 94-V0\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDimension (W x H x D) in mm\u003c\/strong\u003e: 18 x 59 x 90\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWeight (unpacked) Approx.\u003c\/strong\u003e: 70 g\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Base \/ DIN rail\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e: IP 20 for Terminal, IP 30 for Enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eReal-time monitoring of voltage and phase conditions\u003c\/li\u003e\n \t\u003cli\u003eDetects phase loss and incorrect sequence\u003c\/li\u003e\n \t\u003cli\u003eAdjustable over and under-voltage thresholds\u003c\/li\u003e\n \t\u003cli\u003eUser-settable trip delay timing\u003c\/li\u003e\n \t\u003cli\u003eCompact DIN rail mounting\u003c\/li\u003e\n \t\u003cli\u003eLED indication for quick fault identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Voltage Monitoring Relay\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003ePrevents costly electrical damage from voltage faults\u003c\/li\u003e\n \t\u003cli\u003eEnhances equipment lifespan and safety\u003c\/li\u003e\n \t\u003cli\u003eEasy to install and configure\u003c\/li\u003e\n \t\u003cli\u003eSaves time in diagnostics with LED fault display\u003c\/li\u003e\n \t\u003cli\u003eSupports continuous and reliable operations in harsh environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eIndustrial control panels\u003c\/li\u003e\n \t\u003cli\u003eGenerators and backup systems\u003c\/li\u003e\n \t\u003cli\u003ePump and motor control systems\u003c\/li\u003e\n \t\u003cli\u003eCommercial building power distribution\u003c\/li\u003e\n \t\u003cli\u003eHVAC and refrigeration equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow to Use\u003c\/strong\u003e\u003c\/h3\u003e\nTo use the \u003cstrong\u003eGIC MD21DF\u003c\/strong\u003e, mount it on a DIN rail in your electrical panel. Connect the 3-phase supply to its terminals. Set the desired voltage thresholds and trip delay using the onboard dials. Once powered, the relay continuously checks the voltage levels and phase sequence. If the supply goes beyond set limits or a phase error occurs, the relay switches its output to prevent damage to the connected system. LED indicators help identify the exact issue quickly.\n\u003ch3\u003e\u003cstrong\u003eWhy You Should Buy\u003c\/strong\u003e\u003c\/h3\u003e\nThe \u003cstrong\u003eGIC MD21DF voltage monitoring relay\u003c\/strong\u003e is a smart choice for protecting any 3-phase electrical system. It offers \u003cstrong\u003eeasy setup, quick fault detection\u003c\/strong\u003e, and is made by a trusted Indian manufacturer. Ideal for both small control panels and large industrial systems, it ensures reliable protection from electrical issues.\n\u003ch4\u003e\u003cstrong\u003eWhere and Who Uses It\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWhere:\u003c\/strong\u003e Control cabinets, industrial equipment, commercial power panels\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWho:\u003c\/strong\u003e Panel builders, electrical contractors, OEMs, maintenance teams, factory engineers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAbout the Manufacturer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cstrong\u003eGIC India\u003c\/strong\u003e is a leading Indian brand in industrial automation and electrical control products. Known for innovation and quality, GIC manufactures timers, relays, counters, and monitoring devices that meet global standards. Their solutions are widely used in industrial, commercial, and infrastructure applications across India and abroad.","brand":"Voltage Monitoring Series","offers":[{"title":"Default Title","offer_id":43327744606297,"sku":"ECDUVR0001","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/Untitled-design-71.png?v=1779108953"},{"product_id":"rnpp-311m-3-phase-voltage-monitoring-relay-5a-220v","title":"RNPP-311M 3 Phase Voltage Monitoring Relay 5A 220V","description":"\u003ch3\u003e\u003cstrong\u003eThe RNPP-311M voltage monitoring relay is designed for protection of three-phase loads against major types of mains faults, as:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eRMS voltage reaching beyond admissible thresholds;\u003c\/li\u003e\n \t\u003cli\u003ephase sequence order violation and phase coincidence;\u003c\/li\u003e\n \t\u003cli\u003eviolation of the mains voltage phase completeness and symmetry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eThe device performs monitoring of the main circuit parameters and de-energizes load when the parameters fall beyond specified boundaries. The front panel LEDs display the following:\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003epresence of voltage in the mains;\u003c\/li\u003e\n \t\u003cli\u003eload status (ON\/OFF);\u003c\/li\u003e\n \t\u003cli\u003etype of fault.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"THREE-PHASE VOLTAGE AND PHASE MONITORING RELAY","offers":[{"title":"Default Title","offer_id":43327748964441,"sku":"ECDREL0136","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/rnpp-311m-kategoria-eng.jpg?v=1779109054"},{"product_id":"rnpp-301-phase-sequence-relay-3-phase-voltage-monitoring","title":"RNPP-301 phase sequence relay 3 Phase voltage monitoring","description":"\u003ch3\u003eRNPP-301 is designed for the protection of three-phase consumers against the main types of failures in the electric power network.\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003edeviation of voltage RMS value beyond permissible thresholds;\u003c\/li\u003e\n \t\u003cli\u003efailure of phase sequence and sticking;\u003c\/li\u003e\n \t\u003cli\u003efailure of full-phase and symmetry of the supply-line voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eThe device ensures monitoring of the main parameters of the electrical network and disconnects the load in case of deviation.\u003c\/strong\u003e\n\nRelay also provides monitoring of the condition of power contacts of the external magnetic starter before and after load starting by means of control of their operation state (burning or sticking).\n\n\u003cstrong\u003eLEDs at the Relay face panel provide initiation of the following\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eVoltage in the network;\u003c\/li\u003e\n \t\u003cli\u003eLoad condition (ON or OFF);\u003c\/li\u003e\n \t\u003cli\u003eType of failure occurred.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"THREE-PHASE VOLTAGE AND PHASE CONTROL RELAY","offers":[{"title":"Default Title","offer_id":43327748997209,"sku":"ECDREL0137","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/rnpp-311m-kategoria-engkl.jpg?v=1779109054"},{"product_id":"rnpp-302-multifunctional-voltage-monitoring-relay","title":"RNPP-302  MULTIFUNCTIONAL VOLTAGE MONITORING RELAY","description":"\u003ch3\u003e\u003cspan style=\"color: #000000;\"\u003e8A 220V MULTIFUNCTIONAL 3 PHASE VOLTAGE MONITORING RELAY - RNPP-302 is designed for the protection of three-phase loads against the major type of mains faults.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eRMS voltage reaching beyond admissible thresholds;\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ephase sequence order violation and phase coincidence;\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eviolation of the mains voltage phase completeness and symmetry.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eThe device performs monitoring of the main circuit parameters and de-energizes load when the parameters fall beyond specified boundaries. The three-digit, seven-segment display on the relay front panel allows to:\u003c\/strong\u003e\u003c\/span\u003e\n\u003cul\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003econtinuously indicate the actual circuit voltage;\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eindicate the type of occurring fault;\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eview (visualize) settings of modes and parameters.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"voltage monitoring relay","offers":[{"title":"Default Title","offer_id":43327749095513,"sku":"ECDREL0140","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/rn-113-blue-kategoria-engl.jpg?v=1779109056"},{"product_id":"omron-5a-200-480-vac-phase-sequence-phase-loss-relay-k8ds-ph1","title":"Omron 5A, 200\/480 VAC Phase Sequence , Phase Loss Relay - K8DS-PH1","description":"\u003ch3\u003eThree-phase Phase-sequence Phase-loss Relay- K8DS-PH1,  Using Voltage Detection Method.\u003c\/h3\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eThe lineup includes a 17.5-mm slim, compact model.\u003c\/li\u003e\n \t\u003cli\u003eGreater resistance to inverter noise.\u003c\/li\u003e\n \t\u003cli\u003eDistinguishes between correct phases, phase sequence, and phase loss when power is turned ON.\u003c\/li\u003e\n \t\u003cli\u003eSupports phase loss detection when the motor is operating.\u003c\/li\u003e\n \t\u003cli\u003eOutput status can be monitored using an LED indicator.\u003c\/li\u003e\n \t\u003cli\u003eIdeal to prevent reverse operation of motors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"industrial relays","offers":[{"title":"Default Title","offer_id":43327749193817,"sku":"ECDREL0141","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/K8DS-PH1-1003xX.jpg?v=1779109058"},{"product_id":"two-channel-voltage-monitoring-relay-rnpp-311-1","title":"Two-Channel Voltage monitoring relay - RNPP-311-1","description":"\u003ch3\u003eVoltage, Phase Unbalance, and Sequence Relay RNPP-311.1 is designed to disconnect the load 400 V, 50 Hz in case of inadmissible voltage oscillations in the network with a time duration of at least 0.02 s.\u003c\/h3\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eInadmissible voltage oscillations in the network with time duration of at least 0.02 s;\u003c\/li\u003e\n \t\u003cli\u003eAmplitude symmetry breaking of the mains voltage (phase unbalance);\u003c\/li\u003e\n \t\u003cli\u003eLoss, error in sequence, and sticking of the phases.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fequency Relays","offers":[{"title":"Default Title","offer_id":43327749324889,"sku":"ECDREL0143","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/files-writeable-uploads-hostgator22335-image-9-md0x25.jpg?v=1779109061"},{"product_id":"scu01-k8ds-ph1-phase-sequence-phase-loss-relay","title":"SCU01 (K8DS-PH1) Phase Sequence \u0026 Phase Loss Relay","description":"SCU01 (K8DS-PH1) Phase Sequence \u0026amp; Phase Loss Relay\rThe SCU01 (K8DS-PH1) from Omron is a three-phase phase-sequence and phase-loss monitoring relay designed to protect electrical systems and motors. It detects incorrect phase sequence and phase loss using a voltage detection method and provides a reliable SPDT relay output. This compact relay helps prevent reverse motor operation and supports stable monitoring in industrial power systems.\r\rAs an authorised distributor of Omron, E Control Devices supplies genuine SCU01 (K8DS-PH1) relays for industrial automation and electrical protection applications.\r\rThe SCU01 (K8DS-PH1) is a compact phase-monitoring relay designed for three-phase, 3-wire systems with voltages ranging from 200 to 480 VAC. The device detects both phase-sequence errors and phase-loss conditions to help maintain safe and reliable system operation.\r\rThis relay uses a voltage detection method to monitor the power supply and provides a SPDT relay output for control systems. It features LED indicators for monitoring the power and relay status, and its slim 17.5-mm design allows easy installation on DIN rails in control panels.\rKey Features\r\r \tPhase Sequence Monitoring – Detects incorrect phase order in three-phase systems.\r \tPhase Loss Detection – Identifies phase loss when power is turned ON.\r \tMotor Operation Protection – Supports phase loss detection while the motor is operating.\r \tVoltage Detection Method – Ensures reliable monitoring of phase conditions.\r \tSPDT Relay Output – Provides one SPDT relay output for system control.\r \tLED Status Indicators – Includes Power (PWR) and Relay (RY) LED indicators for easy monitoring.\r \tSlim Compact Design – 17.5 mm wide housing suitable for space-saving panel installation.\r \tDIN Rail Mounting – Easy installation on standard DIN tracks.\r \tGreater Resistance to Inverter Noise – Designed to perform reliably in environments with electrical noise.\r \tAutomatic Reset Function – Automatically resets once the fault condition is cleared.\r\rApplications\rThe SCU01 (K8DS-PH1) phase monitoring relay is used in electrical and industrial systems where reliable phase monitoring is required.\r\rCommon applications include:\r\r \tMotor protection systems\r \tIndustrial automation control panels\r \tThree-phase power supply monitoring\r \tMotor control circuits\r \tEquipment requiring phase sequence verification\r \tProtection against reverse motor operation\r \tMonitoring of phase loss in operating motors\r\rThis relay helps maintain correct phase order and detect phase failures, which are critical for maintaining proper operation of three-phase motors and electrical equipment.\rTechnical Specifications\rGeneral Specifications\r\r\r\rParameter\rSpecification\r\r\r\r\rModel\rK8DS-PH1\r\r\rProduct Code\rSCU01\r\r\rRelay Type\rSPDT Relay\r\r\rMonitoring Function\rPhase Sequence and Phase Loss\r\r\rRated Input Voltage\r3-phase, 200 to 480 VAC (3-wire)\r\r\rInput Frequency\r50 \/ 60 Hz\r\r\rInput Load\rApprox. 2.7 VA\r\r\rMounting\rDIN Track\r\r\rDimensions\r17.5 × 80 × 74 mm (W × D × H)\r\r\rWeight\rApprox. 60 g\r\r\r\rOperating Characteristics\r\r\r\rParameter\rValue\r\r\r\r\rPhase Sequence Operating Time\r0.1 s ± 0.05 s\r\r\rPhase Loss Operating Time\r0.1 s max.\r\r\rReset Method\rAutomatic reset\r\r\rIndicators\rPower (Green), Relay Output (Yellow)\r\r\r\rOutput Relay Specifications\r\r\r\rParameter\rValue\r\r\r\r\rRelay Type\rOne SPDT relay (NC operation)\r\r\rRated Load\r5 A at 250 VAC\r\r\rRated Load (DC)\r5 A at 30 VDC\r\r\rMaximum Switching Capacity\r1,250 VA \/ 150 W\r\r\rMinimum Load\r5 VDC, 10 mA (reference value)\r\r\r\rRelay Life\r\r\r\rParameter\rValue\r\r\r\r\rMechanical Life\rMinimum 10 million operations\r\r\rElectrical Life\r50,000 operations (5 A at 250 VAC \/ 30 VDC)\r\r\rElectrical Life\r100,000 operations (3 A at 250 VAC \/ 30 VDC)\r\r\r\rEnvironmental Specifications\r\r\r\rParameter\rSpecification\r\r\r\r\rOperating Temperature\r−20°C to 60°C\r\r\rStorage Temperature\r−25°C to 65°C\r\r\rOperating Humidity\r25% to 85% (no condensation)\r\r\rStorage Humidity\r25% to 85% (no condensation)\r\r\rMaximum Altitude\r2,000 m\r\r\r\rElectrical and Safety Specifications\r\r\r\rParameter\rSpecification\r\r\r\r\rInsulation Resistance\r20 MΩ min.\r\r\rDielectric Strength\r2,000 VAC for 1 minute\r\r\rNoise Immunity\rSquare-wave noise ±1 μs \/ 100 ns pulse width\r\r\rDegree of Protection\rIP20 (terminals)\r\r\rConforming Standards\rEN 60947-5-1\r\r\rSafety Standards\rUL 508, CSA C22.2 No.14, CCC\r\r\r\rBenefits of Using SCU01 (K8DS-PH1)\r\r \tReliable Phase Monitoring: The relay continuously monitors phase sequence and phase loss conditions. This ensures that electrical systems operate only under correct power conditions.\r \tProtection for Three-Phase Motors: Incorrect phase sequence can cause motors to rotate in the wrong direction. This relay helps prevent reverse motor operation, protecting equipment and reducing downtime.\r \tImproved System Safety: Detecting phase loss quickly helps avoid damage to connected equipment. The relay activates within a short operating time when abnormal conditions occur.\r \tEasy Installation: The 17.5 mm slim design allows installation in compact control panels. DIN rail mounting makes installation quick and convenient for industrial environments.\r \tClear Status Monitoring: The built-in LED indicators allow users to easily check power supply and relay output status, making troubleshooting and monitoring simple.\r \tStable Operation in Industrial Environments: The relay offers greater resistance to inverter noise, which improves reliability in automation systems and electrical control panels.\r\rWhy Choose SCU01 (K8DS-PH1) from E Control Devices\rE Control Devices supplies genuine Omron industrial automation components. As an authorised distributor of Omron, the company provides reliable products along with professional support for industrial automation and electrical protection applications.\r\rThe SCU01 (K8DS-PH1) relay is designed to deliver accurate phase monitoring, protect motors from incorrect phase conditions, and maintain the stability of three-phase power systems.","brand":"Phase-sequence Phase-loss Relay","offers":[{"title":"Default Title","offer_id":43327757418585,"sku":"ECDREL0278","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/K8DS-PH.jpg?v=1779109185"},{"product_id":"gic-sm-175-voltage-monitoring-relay","title":"GIC SM 175 Voltage Monitoring Relay","description":"\u003ch3\u003e\u003cspan style=\"color: #000000;\"\u003eGIC SM 175 Voltage Monitoring Compact 17.5 mm Wide\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\n\u003cul class=\"checklist\"\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMulti-Voltage: Three Phase 3 Wire @ 208-480 VAC or Three Phase 4 Wire @ 120-277 VAC\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCan be configured for 3 Phase 3 Wire or 3 Phase 4 Wire system\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProtection against Phase loss, Phase Sequence, Phase Asymmetry, Under Voltage \u0026amp; Over Voltage\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eSelectable Under Voltage \/ Over Voltage, Asymmetry and Phase Sequence\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLED Indication for all Faults \u0026amp; for change in dip switch settings during runtime for better security\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAdjustable ON\/OFF Time Delay in seconds \/ minutes\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1 C\/O Configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GIC Voltage Monitoring Series175","offers":[{"title":"Default Title","offer_id":43327762792537,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/GIC-SM-175-Voltage-Monitoring.png?v=1779109315"},{"product_id":"k8dt-pz2cn-three-phase-voltage-and-phase-sequence-phase-loss-relay","title":"K8DT-PZ2CN Three-phase Voltage and Phase-sequence Phase-loss Relay","description":"\u003ch3\u003eK8DT-PZ2CN Three-phase Voltage, Asymmetry, and Phase-sequence Phase-loss Relay Protect motors and other equipment from unstable voltages in the power supply system. Detect overvoltages, undervoltages, voltage asymmetry, phase sequence, and phase loss for three-phase power supplies.\u003c\/h3\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003e Phase loss detection while the motor is operating.\u003c\/li\u003e\n \t\u003cli\u003e Global power supply support. (Changed with a switch.)\u003c\/li\u003e\n \t\u003cli\u003e Greater resistance to inverter noise.\u003c\/li\u003e\n \t\u003cli\u003e Width of 17.5 mm to reduce space required in panels.\u003c\/li\u003e\n \t\u003cli\u003e Push-In Plus Terminal that reduce wiring work.\u003c\/li\u003e\n \t\u003cli\u003eThe use of cage clamps enables wiring with bare stranded wires.\u003c\/li\u003e\n \t\u003cli\u003eDouble-insertion holes for crossover wiring (all terminals).\u003c\/li\u003e\n \t\u003cli\u003e UL listed for easy shipping to North America.\u003c\/li\u003e\n \t\u003cli\u003e Certified for maritime standards (LR).\u003c\/li\u003e\n \t\u003cli\u003e Models added with transistor outputs for superior contact reliability\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"3- Phase Sequence Relays","offers":[{"title":"Default Title","offer_id":43327768264793,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/K8DT-PZ2CN.png?v=1779109433"},{"product_id":"gic-mac04d0100-voltage-monitoring-relay-3-phase-overvoltage-protection-undervoltage-protection-with-dpdt-contact-configuration","title":"GIC MAC04D0100 Voltage Monitoring Relay 3 Phase Overvoltage Protection Undervoltage Protection with DPDT Contact Configuration","description":"\u003cspan style=\"color: #000000;\"\u003eThe GIC MAC04D0100 Voltage Monitoring Relay has 3 Electrical Phases along with Overvoltage Protection and Under Voltage Protection with DPDT contact configuration. It is the supply monitoring relays with combined phase failure and neutral loss detection. It comes with a screw terminal type. It has some special features such as automatic recovery on fault removal, LED indication for all failure conditions.\u003c\/span\u003e\n\n\u003ch3\u003eGIC MAC04D0100 Voltage Monitoring Relay Specification and Technicle Information\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n  \u003ctable\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eModel No.\u003c\/th\u003e\n      \u003ctd colspan=\"2\"\u003eMAC04D0100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eParameters\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSupply Voltage (Φ)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e415 VAC (Ph-Ph); 3 Phase, 4 Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e47 to 53 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower Consumption (Max.)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e10 VA (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase Loss\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase Sequence\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eTrip Settings\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase Asymmetry\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e94V ± 4V (Ph-Ph)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eUnder Voltage\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e55% to 95% (± 4%)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOver Voltage\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e105% to 125% (± 4%)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e7 V (± 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eON Delay\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e5 s ±1 s (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eTime Delay (OFF Delay)\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTrip Time\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eFor Phase failure\/Imbalance\/Under voltage\/Over voltage: 5 s ±1 s (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eFor Neutral Fail: 500 ms ±1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eOutput\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e5A @ 250 VAC \/ 28 VDC (Resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1×10⁵\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1×10⁶\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eUtilization Category\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAC - 15\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRated Voltage (Ue): 120\/240 V, Rated Current (Ie): 3.0\/1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC - 13\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRated Voltage (Ue): 24\/125\/250 V, Rated Current (Ie): 2.0\/0.22\/0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eLED Indications on Front Plate\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCondition\u003c\/td\u003e\n      \u003ctd\u003eGREEN\u003c\/td\u003e\n      \u003ctd\u003eUV\u003c\/td\u003e\n      \u003ctd\u003eOV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower ON\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase Reverse\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAsymmetry\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eUV\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOV\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase Fail\u003c\/td\u003e\n\u003ctd\u003eBLINK\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase Fail + UV\u003c\/td\u003e\n\u003ctd\u003eBLINK\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase Fail + OV\u003c\/td\u003e\n\u003ctd\u003eBLINK\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNeutral Fail\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eBLINK\u003c\/td\u003e\n\u003ctd\u003eBLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eEnvironmental\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-10°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity (Non Condensing)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e95% (RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\u003cth colspan=\"4\"\u003eEnclosure \u0026amp; Mechanical\u003c\/th\u003e\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eFlame Retardant UL 94-V0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e36 x 90 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight (unpacked)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e120 g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eBase \/ DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIP 20 for Terminals, IP 40 for Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cstrong\u003e\u003cspan style=\"color: #000000;\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\n\u003cdiv id=\"featurebullets_feature_div\" data-feature-name=\"featurebullets\" data-csa-c-id=\"up16ga-o271qg-3kt9pl-wck6l9\" data-cel-widget=\"featurebullets_feature_div\"\u003e\n\u003cdiv id=\"feature-bullets\"\u003e\n\u003cul\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAutomatic Recovery on Fault Removal, LED Indication for All Failure Conditions\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eNeutral Loss, Phase Failure, Phase Reversal, Phase Sequence, Phase Symmetry\u003c\/span\u003e\u003c\/li\u003e\n \t\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eOvervoltage Protection, Under-voltage Protection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"bissProductSpecification_feature_div\" data-feature-name=\"bissProductSpecification\" data-csa-c-id=\"vpyvpx-64w2qm-326o0z-3vwpuj\" data-cel-widget=\"bissProductSpecification_feature_div\"\u003e\u003c\/div\u003e","brand":"GIC","offers":[{"title":"Default Title","offer_id":43327791661145,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/Voltage-Monitoring-Relay-3-Phase.jpg?v=1779110048"},{"product_id":"rnpp-302m-three-phase-programmable-voltage-monitoring-relay","title":"RNPP-302M Three Phase Programmable Voltage Monitoring Relay","description":"The RNPP-302M Voltage Monitoring Relay is the best protective device for three-phase systems against voltage faults. This relay is built to respond to voltage variations in circuits; hence, it disconnects the load once set values are exceeded or undervalued. It’s a multi-functional device featuring under and over-voltage protection, phase loss detection, phase sequence correction, and contactor state monitoring. Such features make it useful in many industries.\r\rWith a built-in LED display, the RNPP-302M can display a true RMS voltage reading of the three-phase system and active electrical system faults, which is fast for the operators. Such selection allows the whole installation to adapt to numerous users’ needs. Furthermore, incorporated menu options simplify user configuration of voltage thresholds, required delay times, and tolerable phase imbalances.\rNotable Features\r\r \tComplete Voltage Protection- It protects against multiple voltage issues, such as under and overvoltages, phase loss, and phase imbalance.\r \tClear LED Display- Shows real-time RMS voltage, various fault LEDs, and the set parameters.\r \tEasy Programming- The user can set the tripping voltages, time delays, and Emergency stop switch.\r \tRemote Control Capabilities- The unit is controlled via a live input for Remote Control and Emergency stop signals.\r \tDurable Design- Its protected housing has an IP40 rating and can withstand a wider temperature range.\r \tStandards Compliance- Qualified performance to IEC 60947-1, IEC 61000-4-2, and a multitude of international electrical standards.\r\r \r\rProtect the stability and safety of your entire three-phase systems with the RNPP-302M Voltage Monitoring Relay. This relay provides comprehensive fault protection while being easy to use, making it the ideal power management relay. Place your order now!","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":43327800279129,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/RNPP-302M-Three-Phase-Programmable-Voltage-Monitoring-Relay.jpg?v=1779110286"}],"url":"https:\/\/econtroldevices.com\/collections\/phase-sequence-relay.oembed","provider":"Econtroldevices","version":"1.0","type":"link"}