{"title":"Vapor Phase Soldering Fluid","description":null,"products":[{"product_id":"galden®-ls-201","title":"GALDEN® LS 200","description":"\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e offers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGALDEN® LS 200\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a fully fluorinated fluid from the GALDEN LS\/HS range by Solvay\/Syensqo, specifically developed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003evapor phase soldering (VPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGALDEN LS 200 belongs to the perfluorinated polyether (PFPE) family. Its narrow molecular weight distribution, strong carbon-fluorine bonds, and flexible ether linkages are characteristics identified by the manufacturer for the GALDEN LS\/HS series.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eboiling point of 200°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, GALDEN LS 200 is designed for industrial vapor phase soldering processes. The fluid provides the thermal and chemical stability, dielectric properties, and material compatibility described in the manufacturer's Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe GALDEN LS\/HS product range includes grades with boiling points from 200°C to 260°C, allowing different vapor temperatures to be selected according to soldering process requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of GALDEN LS 200\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eVapor Phase Soldering Fluid:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically developed as part of the GALDEN LS\/HS range for VPS applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFully Fluorinated Composition:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Identified as a perfluorinated polyether fluid.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBoiling Point:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 200°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNarrow Molecular Weight Distribution:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports process stability and repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThermal and Chemical Stability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Documented as a characteristic of the GALDEN LS\/HS range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNonflammable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Confirmed in the manufacturer's Safety Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNo Autoignition Point:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Identified as a feature of the GALDEN LS\/HS range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLow Heat of Vaporization:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 63 J\/g at the boiling point.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eVapor Density Greater Than Air:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Identified as a characteristic of the product range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRapid and Residue-Free Drying:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Listed as a benefit of the GALDEN LS\/HS range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDensity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1.79 g\/cm³.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKinematic Viscosity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.50 cSt.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThermal Conductivity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.07 W\/m·°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 40 kV at a 2.54 mm gap.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Constant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.1.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications of GALDEN LS 200\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet identifies GALDEN LS\/HS fluids specifically for vapor phase soldering applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e1. Vapor Phase Soldering (VPS)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eGALDEN LS 200 is part of the GALDEN LS\/HS range developed for vapor phase soldering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe product's 200°C boiling point is documented in the manufacturer's Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. Lead-Free Soldering Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's product literature discusses GALDEN LS\/HS fluids in relation to lead-free soldering processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe range offers different boiling-point grades to support the temperature requirements of lead-free soldering applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. Printed Circuit Board Assembly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet discusses lead-free printed circuit board assembly (PCBA) manufacturing in connection with vapor phase soldering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGALDEN LS 200 belongs to the range developed for this soldering process.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. Electronic Equipment Manufacturing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe GALDEN LS\/HS range is identified for vapor phase soldering processes used in electronic equipment manufacturing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. Industrial Heat Transfer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Safety Data Sheet identifies GALDEN LS 200 as a heat transfer medium intended for industrial use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications of GALDEN LS 200\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe following values are taken from the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLS200 column on page 2 of the supplied GALDEN LS and HS Vapor Phase Soldering Fluids Technical Data Sheet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eProperty\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eGALDEN LS 200 Specification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGALDEN® LS 200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGALDEN LS\/HS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChemical Nature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePerfluorinated Polyethers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical State\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eColorless\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOdor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOdorless\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBoiling Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDensity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.79 g\/cm³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKinematic Viscosity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.50 cSt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVapor Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21 Pa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecific Heat\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e973 J\/kg·°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeat of Vaporization at Boiling Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63 J\/g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Conductivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.07 W\/m·°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoefficient of Expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0011 cm³\/cm³·°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Tension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 dyne\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Strength at 2.54 mm Gap\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Constant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVolume Resistivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 10¹⁶ Ohm·cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAverage Molecular Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e870 amu\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlammability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNonflammable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eThese values are typical manufacturer-reported physical properties at 25°C unless otherwise specified. They are not guaranteed product specifications.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eChemical Composition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's Safety Data Sheet (Version 4.00, dated January 15, 2026), GALDEN LS 200 is a perfluorinated polyether substance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eChemical Component\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eCAS Number\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eConcentration\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1-Propene, 1,1,2,3,3,3-hexafluoro-, oxidized, polymd.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69991-67-9\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 99.9%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer identifies GALDEN LS 200 as a substance rather than a mixture.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet also notes that the specific chemical identity and\/or exact concentration percentage has been withheld as a trade secret.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eVapor Phase Soldering Performance\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003ePrecise Vapor Temperature\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet identifies different boiling-point grades within the GALDEN LS\/HS range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGALDEN LS 200 has a boiling point of 200°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer states that precise vapor temperatures help eliminate overheating during vapor phase soldering processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProcess Stability and Repeatability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe narrow molecular weight distribution of GALDEN LS\/HS fluids supports process stability and repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer also identifies no boiling point drift as a benefit of the product range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRapid and Residue-Free Drying\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe GALDEN LS\/HS Technical Data Sheet identifies low heat of vaporization and vapor density greater than air as product characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese properties are associated with rapid and residue-free drying during vapor phase soldering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHeating in an Inert Atmosphere\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer describes preheating and heating processes taking place in an inert atmosphere during vapor phase soldering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThermal and Chemical Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe GALDEN LS\/HS series is described as having excellent thermal and chemical stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe GALDEN LS200 Safety Data Sheet also states that product degradation was not observed in vapor phase soldering applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eElectrical Properties\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet reports the following electrical properties for GALDEN LS 200.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eElectrical Property\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eReported Value\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 kV at 2.54 mm gap\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Constant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVolume Resistivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × 10¹⁶ Ohm·cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThese are typical manufacturer-reported values.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMaterial Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GALDEN LS\/HS Technical Data Sheet identifies good material compatibility as a characteristic of the product range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompatibility with Construction Materials\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer, GALDEN LS\/HS fluids provide good compatibility with materials of construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe product literature also identifies no corrosion or reaction with materials of construction as a benefit of the fluid range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMaterial Compatibility Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied documents do not provide a detailed GALDEN LS200-specific compatibility table for metals, plastics, or elastomers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaterial suitability should therefore be evaluated for the specific application and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAvailable Packaging Sizes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product screenshot identifies the following packaging options:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003ePackaging Type\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBottle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSample\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 lb \/ 1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003ePackaging availability should be confirmed when requesting a quotation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eStorage and Handling\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eGALDEN LS 200 is intended for industrial use only.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStorage Guidelines\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's Safety Data Sheet:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep the fluid in properly labeled containers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStore away from heat and sources of ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep away from combustible materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep away from incompatible substances.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlastic materials and glass are identified as suitable packaging materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHandling Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure adequate ventilation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse appropriate personal protective equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvoid overheating to prevent thermal decomposition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTake precautions against electrostatic charge buildup.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure equipment is electrically grounded before transfer operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClean and dry piping circuits and equipment before use.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFollow industrial hygiene and safety practices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's Safety Data Sheet dated January 15, 2026, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGALDEN LS 200 is not classified as hazardous under the OSHA Hazard Communication Standard (29 CFR 1910.1200)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer also identifies the fluid as nonflammable and not explosive.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Temperature Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet reports a decomposition temperature above 290°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOverheating or exposure to fire may produce hazardous decomposition products, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGaseous Hydrogen Fluoride (HF)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFluorophosgene\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIncompatible Materials\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer identifies:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlkali Metals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLewis Acids (Friedel-Crafts) above 100°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAluminum and Magnesium in Powder Form above 200°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003ePersonal Protective Equipment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet recommends:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChemical-resistant protective gloves\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety glasses with side shields\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtective work clothing and safety shoes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAppropriate respiratory protection when required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eWhen splashing may occur, tightly fitting safety goggles and a chemical-resistant apron are recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEnvironmental and Regulatory Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eChemical Inventory Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Safety Data Sheet identifies GALDEN LS 200 on the following chemical inventories:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnited States TSCA Inventory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCanadian Domestic Substances List\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAustralian Inventory of Industrial Chemicals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKorean Existing Chemicals Inventory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChina's Existing Chemical Substances Inventory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eJapanese Chemical Inventories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhilippines Inventory of Chemicals and Chemical Substances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNew Zealand Chemical Substances Inventory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTaiwan Chemical Substance Inventory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet also provides specific conditions concerning Japanese importation and European REACH compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eEnvironmental Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer states that GALDEN LS 200 should not be released into the environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe fluid must not be discharged into drains, watercourses, or soil.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied Technical Data Sheet and Safety Data Sheet do not provide a product-specific global warming potential or ozone depletion potential value for GALDEN LS 200.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRecycling and Disposal\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Safety Data Sheet provides disposal guidance for GALDEN LS 200.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDisposal Guidelines\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDo not dispose of the fluid into sewers, soil, or bodies of water.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFollow applicable local, regional, and national disposal regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncineration may be used where permitted by local regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncineration facilities must have systems for neutralizing or recovering hydrogen fluoride.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEmpty containers may be landfilled where local regulations permit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFluid Reclamation Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product screenshot includes information about TMC Industries' reclamation services for used fluorinated fluids and solvents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis information relates to TMC Industries' services and does not represent a reclamation guarantee directly provided by Econtrol Devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eGALDEN LS 200 – Product Inquiries at Econtrol Devices\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides product information and quotation assistance for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGALDEN® LS 200 Vapor Phase Soldering Fluid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor technical specifications, packaging details, safety documentation, or quotations, contact \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSafety Information:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e GALDEN LS 200 is intended for industrial use only. Although the product is not classified as hazardous under OSHA GHS, overheating can produce hazardous decomposition substances. Review the manufacturer's current Technical Data Sheet, Safety Data Sheet, and product label before handling or using the fluid.\u003c\/span\u003e\u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":47709393715289,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/opteon_sf10_6kg.webp?v=1793606086"}],"url":"https:\/\/econtroldevices.com\/collections\/vapor-phase-soldering-fluid.oembed","provider":"Econtroldevices","version":"1.0","type":"link"}