{"product_id":"ad-7100-fluorinated-engineering-fluid","title":"AD-7100 Fluorinated Engineering Fluid","description":"\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e offers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAD-7100 Fluorinated Engineering Fluid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a clear, colorless fluorinated liquid manufactured by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNantong A.D Dawning Materials Co., Ltd.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for industrial cleaning, heat transfer, and electronic applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 contains methoxy-nonafluorobutane (C₄F₉OCH₃) and is described by the manufacturer as nonflammable, chemically inert, and thermally stable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product listing identifies AD-7100 as a replacement for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3M™ Novec™ 7100\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, offering similar chemistry and physical properties. The product is also listed under the trade names \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePFE-10, PFE-5100, TF-7100, and SM-7100\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is intended for industrial cleaning and rinsing, heat transfer, dielectric testing, lubricant fluid, and specialty solvent applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of AD-7100 Fluorinated Engineering Fluid\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3M™ Novec™ 7100 Replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Listed as a replacement fluid in the supplied product information.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFluorinated Engineered Fluid:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Contains methoxy-nonafluorobutane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eChemically Inert:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Described as chemically inert in the manufacturer's Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThermal Stability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for the listed industrial and electronic applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNonflammable Fluid:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reported as nonflammable by the manufacturer, with no flash point identified in the Safety Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectronic Cleaning Applications:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Intended for industrial cleaning and rinsing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHeat Transfer Applications:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Listed as a heat transfer fluid in the Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Used as dielectric test media.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLow Viscosity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Kinematic viscosity of 0.38 cSt.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBoiling Point:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 61°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOzone Depletion Potential:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eGlobal Warming Potential:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 300.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications of AD-7100 Fluorinated Engineering Fluid\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is intended for industrial cleaning, heat transfer, specialty solvent, and electronic applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e1. Industrial Cleaning and Rinsing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet identifies AD-7100 for cleaning and rinsing applications involving:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeavy oils\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrease\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFluxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWaxes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSurface contamination debris\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFluoropolymers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e2. Heat Transfer Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is listed as a heat transfer fluid for industrial and electronic applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product screenshot also identifies heat transfer applications involving semiconductor manufacturing equipment such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEtchers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIon Implanters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTesters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e3. Dielectric Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer lists AD-7100 for use as dielectric test media.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. Lubricant Fluid Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is identified for lubricant fluid applications in the manufacturer's Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. Specialty Solvent Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe fluid is also listed for use as a specialty solvent.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e6. Semiconductor Manufacturing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied product listing describes heat transfer applications involving semiconductor manufacturing equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e7. Data Centers and High-Performance Computing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is listed in the supplied product information for heat transfer applications in data centers and high-performance computing equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e8. Power Electronics and Avionics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe product listing identifies power electronics and avionics among the intended applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications of AD-7100\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe following technical specifications are taken from the manufacturer's AD-7100 Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eProperty\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eAD-7100 Specification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAD-7100 Fluorinated Engineering Fluid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNantong A.D Dawning Materials Co., Ltd.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChemical Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMethoxy-nonafluorobutane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChemical Formula\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC₄F₉OCH₃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical State\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eColorless\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAverage Molecular Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 g\/mol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBoiling Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e61°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePour Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-135°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalculated Critical Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e195°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVapor Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26 kPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid Density at 25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1520 kg\/m³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKinematic Viscosity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 cSt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAbsolute Viscosity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.58 cP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid Specific Heat\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1183 J\/kg·K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Tension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.6 mN\/m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 40 kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Constant at 1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVolume Resistivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10⁸ Ohm·cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSolubility of Solvent in Water\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSolubility of Water in Solvent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOzone Depletion Potential (ODP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal Warming Potential (GWP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlash Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eThese are manufacturer-reported technical values and are not guaranteed specifications. The Safety Data Sheet provides additional physical and chemical information.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eChemical Composition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's Safety Data Sheet (Version 5.0), AD-7100 contains the following components:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eChemical Component\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eCAS Number\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eComposition\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMethyl Perfluorobutyl Ether\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e163702-07-6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–45% by weight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMethyl Perfluoroisobutyl Ether\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e163702-08-7\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55–90% by weight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet identifies AD-7100 as a fluorinated engineered fluid containing these two components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMaterial Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet states that AD-7100 is compatible with most metals and hard polymers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMetals and Hard Polymers\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is identified as compatible with most metals and hard polymers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied Technical Data Sheet does not provide a detailed list of individually tested metal or polymer grades.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSoft Elastomeric Materials\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer recommends using soft elastomeric materials containing the least amount of extractable plasticizer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFluorinated Plastics and Elastomers\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer, AD-7100 may be absorbed into fluorinated plastics and elastomers during prolonged exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaterial compatibility should be assessed according to the intended application, exposure duration, and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAvailable Packaging Sizes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer lists the following packaging options for AD-7100 Fluorinated Engineering Fluid:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003ePackaging Type\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eContainer Capacity\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCan\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePail\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDrum\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThese sizes are taken from the manufacturer's Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eStorage and Handling\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is intended for industrial use only.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStorage Guidelines\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStore the product in a tightly closed original container.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep away from strong acids.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep away from strong bases.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep away from oxidizing agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFollow the manufacturer's storage instructions and applicable regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHandling Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvoid inhaling thermal decomposition products.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvoid release to the environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvoid contact with oxidizing agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDo not eat or smoke while handling the product.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse appropriate local exhaust ventilation when extreme overheating may occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFollow the manufacturer's personal protective equipment recommendations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's Safety Data Sheet, AD-7100 is not classified as hazardous under the OSHA Hazard Communication Standard, 29 CFR 1910.1200.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer reports no flash point and identifies the product as nonflammable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThermal Decomposition\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eUnder extreme heat or combustion conditions, possible decomposition products include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCarbon Monoxide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCarbon Dioxide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHydrogen Fluoride\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eOccupational Exposure Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet lists an AIHA time-weighted average (TWA) exposure limit of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e750 ppm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for each of the two chemical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIndustrial Use Restrictions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 is intended for industrial use only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer states that it is not intended for medical devices, drugs, or consumer applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEnvironmental and Regulatory Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer reports the following environmental properties:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eProperty\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eAD-7100 Value\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOzone Depletion Potential (ODP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal Warming Potential (GWP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the Safety Data Sheet, the required components of AD-7100 are listed on the active portion of the U.S. TSCA Inventory.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe SDS also provides chemical inventory compliance information for Australia, Canada, China, South Korea, Japan, and the Philippines.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDisposal Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAD-7100 must be disposed of in accordance with applicable local and national regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDisposal Guidelines\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDispose of waste material at a permitted industrial waste facility.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFollow applicable waste classification and disposal requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure combustion facilities can handle hydrogen fluoride.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEmpty and cleaned containers may be disposed of as non-hazardous waste where permitted.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAD-7100 Fluorinated Engineering Fluid – Product Inquiries at Econtrol Devices\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides product information and quotation assistance for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAD-7100 Fluorinated Engineering Fluid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor product specifications, packaging options, and quotations related to AD-7100, contact \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSafety Information:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e AD-7100 is intended for industrial use only and is not intended for medical devices, drugs, or consumer applications. Review the manufacturer's current Technical Data Sheet, Safety Data Sheet, and product label before handling, storing, or using the fluid.\u003c\/span\u003e\u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":47689251356761,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/1_Gallon_Jug_6beb6d7e-03e4-4ddb-9a21-33ebe6c576e7.webp?v=1793424114","url":"https:\/\/econtroldevices.com\/products\/ad-7100-fluorinated-engineering-fluid","provider":"Econtroldevices","version":"1.0","type":"link"}