{"product_id":"l-t-gic-12sdt0-micon-175-star-delta-start-timer-240vac","title":"L\u0026T GIC 12SDT0 Micon 175 Star Delta Start Timer 240VAC","description":"\u003cdiv data-csa-c-id=\"ysf5b6-vc9ppx-228uss-tbjkxx\" data-cel-widget=\"dpx-product-description_csm_instrumentation_wrapper\"\u003e\n\u003cdiv id=\"descriptionAndDetails\"\u003e\n\u003cdiv id=\"productDescription_feature_div\" data-feature-name=\"productDescription\" data-csa-c-id=\"mj38fz-8ndkfm-vieiyq-poofhg\" data-cel-widget=\"productDescription_feature_div\"\u003e\n\u003cdiv id=\"productDescription_feature_div\" data-feature-name=\"productDescription\" data-template-name=\"productDescription\" data-cel-widget=\"productDescription_feature_div\"\u003e\n\u003cdiv id=\"productDescription\"\u003e\n\nBoost the efficiency and longevity of your motor control systems with the \u003cstrong data-start=\"258\" data-end=\"309\"\u003eL\u0026amp;T GIC 12SDT0 Micon 175 Star Delta Start Timer\u003c\/strong\u003e. Designed for seamless \u003cstrong data-start=\"333\" data-end=\"358\"\u003estar-delta transition\u003c\/strong\u003e, this high-performance timer ensures reduced inrush current, smooth motor start-up, and enhanced operational reliability.\n\u003ch4 data-start=\"483\" data-end=\"507\"\u003e\u003cstrong data-start=\"488\" data-end=\"505\"\u003eKey Benefits:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOptimized Motor Start-Up\u003c\/strong\u003e – Reduces mechanical stress and voltage drops during motor startup, improving equipment lifespan.\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh Precision Timing\u003c\/strong\u003e – Adjustable time delay from \u003cstrong data-start=\"696\" data-end=\"716\"\u003e3 to 120 seconds\u003c\/strong\u003e with \u003cstrong data-start=\"722\" data-end=\"746\"\u003e±5% setting accuracy\u003c\/strong\u003e, ensuring consistent performance.\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eReliable Performance\u003c\/strong\u003e – Features a \u003cstrong data-start=\"823\" data-end=\"849\"\u003erepeat accuracy of ±1%\u003c\/strong\u003e, making it ideal for applications that demand precision.\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUser-Friendly Operation\u003c\/strong\u003e – LED indicators for clear status monitoring and quick troubleshooting.\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eVersatile Applications\u003c\/strong\u003e – Suitable for industries like \u003cstrong data-start=\"1073\" data-end=\"1129\"\u003emanufacturing, automation, HVAC, and pumping systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Feature\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eModels No.\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003e12SDT0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" colspan=\"4\"\u003e\u003cstrong\u003eParameters\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Description\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eStar Delta Timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eStar Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Diagram\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cimg class=\"diagram aligncenter\" src=\"https:\/\/econtroldevices.com\/wp-content\/uploads\/2025\/06\/1.png\" alt=\"Functional Diagram\" width=\"398\" height=\"257\"\u003e\n\u003c!-- Replace with actual image if needed --\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage (Φ)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Variation\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e-20% to +10% (of Φ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (Max.)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e10 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming Ranges\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e3s to 120s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePause Time\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e60 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Time\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e150 ms (Max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e± 5% of Full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeat Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" colspan=\"4\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eStar - 1 'NO', Delta - 1 'NO'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e5A @ 240 VAC \/ 3A @ 30 VDC (Resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e1×10⁵\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e5×10⁶\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" colspan=\"4\"\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - 15\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRated Voltage (Ue): 120\/240 V, Rated Current (Ie): 3.0\/1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC - 13\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eRated Voltage (Ue): 24\/125\/250 V, Rated Current (Ie): 2.0\/0.22\/0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e-10°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (Non-Condensing)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e95% (RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indication\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eRed LED 1 → 'Y' ON, Red LED 2 → 'Δ' ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eFlame Retardant UL94-V0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension (W x H x D) in mm\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e17.5 X 90 X 58.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (unpacked)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003e65 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eBase \/ DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"3\"\u003eIP 20 for Terminals, IP 40 for Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose L\u0026amp;T GIC Star Delta Timer?\u003c\/strong\u003e\u003c\/h3\u003e\nBuilt with \u003cstrong data-start=\"1778\" data-end=\"1830\"\u003ehigh-quality, flame-retardant materials (UL94-V0)\u003c\/strong\u003e and tested for durability, the L\u0026amp;T GIC 12SDT0 ensures reliable \u003cstrong data-start=\"1894\" data-end=\"1918\"\u003estar-delta switching\u003c\/strong\u003e for optimal motor efficiency. Whether you're upgrading existing systems or installing new motor control panels, this timer is a must-have for smooth and safe operations.\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GIC","offers":[{"title":"Default Title","offer_id":43327791530073,"sku":"2","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/timer.jpg?v=1779110045","url":"https:\/\/econtroldevices.com\/products\/l-t-gic-12sdt0-micon-175-star-delta-start-timer-240vac","provider":"Econtroldevices","version":"1.0","type":"link"}