{"product_id":"opteon™-sf79-specialty-fluid-chemours","title":"OPTEON™ SF79 Specialty Fluid – Chemours","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEcontrol Devices\u003c\/b\u003e offers \u003cb\u003eOPTEON™ SF79 Specialty Fluid\u003c\/b\u003e, a high-solvency industrial cleaning fluid developed by \u003cb\u003eThe Chemours Company\u003c\/b\u003e for precision cleaning, vapor degreasing, defluxing, and the removal of industrial contaminants.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 is a solvent blend containing trans-1,2-dichloroethylene and proprietary methoxytridecafluoroheptene isomers. It has azeotrope-like properties and a Kauri-Butanol (Kb) value of 103, which the manufacturer identifies as the highest solvency power in its class.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eWith a boiling point of 47°C, low surface tension, and strong cleaning performance, Opteon SF79 is developed for industrial processes involving oils, grease, silicone, flux residues, and other contaminants.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAccording to Chemours, the fluid is intended as an alternative to cleaning solvents such as trichloroethylene (TCE), n-propyl bromide (nPB), perchloroethylene, methylene chloride, HCFC-225, HCFC-141b, and certain HFE and PFC fluids.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features of OPTEON SF79 Specialty Fluid\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eHigh Solvency Power:\u003c\/b\u003e Kb value of 103, measured using ASTM D1133.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003ePrecision Cleaning Fluid:\u003c\/b\u003e Developed for industrial cleaning processes requiring strong solvency.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eVapor Degreasing Applications:\u003c\/b\u003e Designed for use in vapor degreasing equipment.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eFast Drying:\u003c\/b\u003e The 47°C boiling point supports faster drying and subsequent processing of cleaned parts.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eLow Surface Tension:\u003c\/b\u003e Supports cleaning applications involving industrial components.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eAzeotrope-Like Properties:\u003c\/b\u003e The manufacturer reports compositional stability during use.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eHigh Soil Loading Capacity:\u003c\/b\u003e Designed to reduce equipment downtime associated with solvent change-outs.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eNo Surfactants Required:\u003c\/b\u003e The manufacturer states that surfactants are not needed for residue-free cleaning.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eLow Global Warming Potential:\u003c\/b\u003e GWP below 15, according to the Technical Information document.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eNegligible Ozone Depletion Potential:\u003c\/b\u003e As reported by Chemours.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eRecyclable and Reusable:\u003c\/b\u003e Listed as recyclable and reusable in the manufacturer's Technical Information document.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\n\u003cb\u003eNo Closed-Cup or Open-Cup Flash Point:\u003c\/b\u003e Reported in manufacturer testing; flammable vapor-air mixtures may nevertheless form during use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplications of OPTEON SF79\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 is intended for a range of industrial precision cleaning applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e1. Oil and Grease Removal\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 is developed for cleaning applications involving oils, greases, and other industrial contaminants.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer reports cleaning performance evaluations involving mineral oil, hydraulic fluid, and grease.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e2. Precision Cleaning\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe fluid is used in industrial precision cleaning processes where high solvency and low surface tension are required.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e3. High-Solvency Defluxing\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 is listed for high-solvency defluxing applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eChemours reports that the fluid was effective in cleaning non-polar flux rosin residues from surface-mounted technology printed circuit boards during its performance evaluations.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e4. Silicone Removal\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 is used for silicone removal applications. The manufacturer's solubility testing identifies silicone DC-704 as miscible with the fluid.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e5. Vapor Degreasing\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe fluid is designed for vapor degreasing applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAccording to Chemours, existing vapor degreasing equipment can generally be used with minor or no modifications, subject to the manufacturer's retrofit guidelines.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e6. Cold Cleaning\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 is also listed for industrial cold cleaning applications.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eTechnical Specifications of OPTEON SF79\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe following values are taken from the manufacturer's Technical Information document.\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eProperty\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOPTEON SF79 Specification\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Name\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon™ SF79 Specialty Fluid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Chemours Company FC, LLC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSpecialty Cleaning Fluid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePhysical Form\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLiquid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eColor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eClear, Colorless\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eBoiling Point\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e47°C (117°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLiquid Density at 25°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1.29 g\/cm³\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSaturated Vapor Density at 25°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1.81 kg\/m³\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSurface Tension at 25°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e21 dyn\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVapor Pressure at 25°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e44.7 kPa\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eDynamic Viscosity at 25°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e0.42 cP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLiquid Thermal Conductivity at 25°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e128 mW\/m·K\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat Capacity at 25°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1.069 kJ\/kg·°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHeat of Vaporization at Boiling Point\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e280 kJ\/kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eKauri-Butanol (Kb) Value\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e103\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFlash Point – ASTM D56\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eFlash Point – ASTM D1310\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 18;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVapor Flammability Limits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e7.25–15.25 vol%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 19;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOzone Depletion Potential\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNegligible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 20;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGlobal Warming Potential (GWP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eLess than 15\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 21;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eVolatile Organic Compounds (VOC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1278 g\/L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 22; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eOccupational Exposure Limit (8-hour TWA)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e201 ppm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eAll physical-property values are reported at 25°C unless otherwise specified. These are manufacturer-reported values, not guaranteed product specifications.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eChemical Composition\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAccording to the manufacturer's Safety Data Sheet, Opteon SF79 is a mixture containing:\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eChemical Component\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCAS Number\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eComposition\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eTrans-Dichloroethylene\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e156-60-5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e90–100% by weight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eMethoxytridecafluoroheptene Isomers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eNot Assigned\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e1% to less than 5% by weight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003eThe exact concentrations are withheld as a trade secret.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCleaning Performance\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eChemours evaluated Opteon SF79 through cleaning tests conducted according to ASTM G122.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eContaminant Removal Performance\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eContaminant\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInitial Contamination\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eAverage Removal\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eMineral Oil\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e2 mg\/cm²\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eHydraulic Fluid (MIL-PRF-83282)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e3.29 mg\/cm²\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eGrease (MIL-PRF-81322)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e16.27 mg\/cm²\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e100%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003ci\u003eThe figures are from the manufacturer's reported tests, averaged across three trials. They should not be interpreted as guaranteed results under all cleaning conditions.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSolubility of Industrial Contaminants\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer lists the following contaminants as miscible with Opteon SF79:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\"\u003eMineral Oil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\"\u003eHydraulic Fluid (MIL-PRF-83282)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\"\u003eGrease (MIL-PRF-81322)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\"\u003eSilicone (DC-704)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo2; tab-stops: list 36.0pt;\"\u003eSkydrol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eMaterial Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eChemours provides material compatibility information based on testing with different metals, plastics, and elastomers.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCompatible Metals\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer reports good compatibility following two weeks of testing at 47°C with:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo3; tab-stops: list 36.0pt;\"\u003eStainless Steel\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo3; tab-stops: list 36.0pt;\"\u003eCopper\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo3; tab-stops: list 36.0pt;\"\u003eBrass\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l6 level1 lfo3; tab-stops: list 36.0pt;\"\u003eAluminum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCompatible Plastics\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer's Technical Information document lists the following plastics as compatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003ePolyethylene\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003ePolypropylene\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003eTeflon™\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003ePolyester\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003eNylon\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003eFEP\/PFA\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003eHalar\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l7 level1 lfo4; tab-stops: list 36.0pt;\"\u003eKynar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eIncompatible Plastics\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer identifies the following plastics as incompatible:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l8 level1 lfo5; tab-stops: list 36.0pt;\"\u003ePolystyrene\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l8 level1 lfo5; tab-stops: list 36.0pt;\"\u003ePolycarbonate\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l8 level1 lfo5; tab-stops: list 36.0pt;\"\u003eABS\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l8 level1 lfo5; tab-stops: list 36.0pt;\"\u003ePolyacrylate\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l8 level1 lfo5; tab-stops: list 36.0pt;\"\u003eAcrylic (PMMA)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l8 level1 lfo5; tab-stops: list 36.0pt;\"\u003ePolysulfone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eElastomer Compatibility\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer identifies Teflon™, Kalrez, Ryton, PTFE with EPDM, PTFE with Neoprene, and Parafluor among the compatible materials in its elastomer compatibility table.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIt identifies silicone, Hypalon, EPDM rubber, Viton™, Buna N, and fluorosilicone as incompatible in that table.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eMaterial Compatibility Precautions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eChemours reports that several elastomers may experience reversible swelling when exposed to Opteon SF79.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer recommends Teflon™ or Teflon-encapsulated gaskets and O-ring seals for diaphragm pumps.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMaterial compatibility should be verified under the expected operating conditions because specific plastic and elastomer formulations may differ.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSafety and Environmental Information\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 has no reported open-cup or closed-cup flash point and is classified as a nonflammable liquid by NFPA and DOT, according to its Technical Information document.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eHowever, \u003cb\u003ethe Safety Data Sheet warns that flammable or explosive vapor-air mixtures may form during use\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEnvironmental Properties\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo6; tab-stops: list 36.0pt;\"\u003eGlobal Warming Potential: Less than 15\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo6; tab-stops: list 36.0pt;\"\u003eOzone Depletion Potential: Negligible\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo6; tab-stops: list 36.0pt;\"\u003eRecyclable and Reusable: Listed in manufacturer documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSafety Classification\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAccording to the Safety Data Sheet, Opteon SF79 is classified under the OSHA Hazard Communication Standard as:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l9 level1 lfo7; tab-stops: list 36.0pt;\"\u003eEye Irritation – Category 2B\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l9 level1 lfo7; tab-stops: list 36.0pt;\"\u003eSpecific Target Organ Toxicity, Single Exposure – Category 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe product may cause eye irritation, drowsiness, or dizziness.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Safety Data Sheet also warns that vapors may displace oxygen and that rapid evaporation may cause frostbite.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eStorage and Handling\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 should be handled in accordance with the manufacturer's Safety Data Sheet.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eStorage Guidelines\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo8; tab-stops: list 36.0pt;\"\u003eStore in a clean, cool, well-ventilated area.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo8; tab-stops: list 36.0pt;\"\u003eKeep containers properly labeled.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo8; tab-stops: list 36.0pt;\"\u003eStore away from direct sunlight.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo8; tab-stops: list 36.0pt;\"\u003eKeep the storage temperature below 46°C (115°F).\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo8; tab-stops: list 36.0pt;\"\u003eDo not expose drums to direct heat.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo8; tab-stops: list 36.0pt;\"\u003eStore locked up.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo8; tab-stops: list 36.0pt;\"\u003eFollow applicable national storage regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eHandling Precautions\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo9; tab-stops: list 36.0pt;\"\u003eUse adequate ventilation and appropriate local exhaust ventilation where required.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo9; tab-stops: list 36.0pt;\"\u003eAvoid breathing mists or vapors.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo9; tab-stops: list 36.0pt;\"\u003eAvoid contact with skin, clothing, and eyes.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo9; tab-stops: list 36.0pt;\"\u003eKeep away from heat and ignition sources.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo9; tab-stops: list 36.0pt;\"\u003eTake precautions against static discharge.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo9; tab-stops: list 36.0pt;\"\u003eUse appropriate chemical-resistant gloves and safety goggles.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l5 level1 lfo9; tab-stops: list 36.0pt;\"\u003eUse a drum pump when dispensing from pails or drums containing 5 gallons or more, as recommended by the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eAvailable Packaging Options\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe supplied product screenshot lists the following packaging options:\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"0\" cellpadding=\"0\" style=\"mso-cellspacing: 1.5pt; mso-yfti-tbllook: 1184;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003ePackaging Type\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eVolume\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eJug\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e10 lb \/ 4.5 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e0.9 gal \/ 3.5 L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003ePail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e45 lb \/ 20 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e4.1 gal \/ 15.6 L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eDrum\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e500 lb \/ 227 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e46.8 gal \/ 177 L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003eSample\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e2.2 lb \/ 1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding: .75pt .75pt .75pt .75pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e0.2 gal \/ 0.7 L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003ePackaging and availability should be confirmed when requesting a quotation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eRecycling and Disposal\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eOpteon SF79 is identified as recyclable and reusable in Chemours' Technical Information document.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe manufacturer states that the product's azeotrope-like properties support compositional stability during use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDisposal Guidelines\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo10; tab-stops: list 36.0pt;\"\u003eDispose of waste according to applicable local regulations.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo10; tab-stops: list 36.0pt;\"\u003eDo not dispose of waste into sewers.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo10; tab-stops: list 36.0pt;\"\u003eTake empty contaminated containers to an approved waste-handling facility for recycling or disposal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eOPTEON SF79 – Product Inquiries at Econtrol Devices\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEcontrol Devices\u003c\/b\u003e provides product information and quotation assistance for \u003cb\u003eOpteon™ SF79 Specialty Fluid\u003c\/b\u003e and industrial cleaning solvent requirements.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFor technical specifications, packaging options, and quotation inquiries related to Opteon SF79, contact \u003cb\u003eEcontrol Devices\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSafety Information:\u003c\/b\u003e Opteon SF79 is restricted to professional users and should only be used for its specified cleaning applications. Review the manufacturer's current Safety Data Sheet and product label before handling, storing, or using the fluid.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":47682204794969,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/opteon_sf_79_pail_6df355fe-c7df-4712-9870-39611cbb09bb.jpg?v=1793363012","url":"https:\/\/econtroldevices.com\/products\/opteon%e2%84%a2-sf79-specialty-fluid-chemours","provider":"Econtroldevices","version":"1.0","type":"link"}