{"product_id":"tmc-7000-engineered-fluid","title":"TMC-7000 Engineered Fluid","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, an authorized distributor of TMC Industries products, offers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTMC-7000 Engineered Fluid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a clear, colorless, thermally stable dielectric fluid developed for industrial heat transfer applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufactured by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTMC Industries, Inc.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, TMC-7000 is a miscible, drop-in replacement for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3M™ Novec™ 7000\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The fluid contains methyl perfluoropropyl ether and is intended for use in semiconductor manufacturing, electronics, and chemical manufacturing industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccording to TMC Industries, the fluid supports extreme low-temperature operation down to -120°C. Its thermal and electrical properties make it useful for the heat transfer applications identified in the manufacturer's Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of TMC-7000 Engineered Fluid\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3M™ Novec™ 7000 Replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Identified by TMC Industries as a miscible, drop-in replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Heat Transfer Fluid:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Developed for heat transfer applications in industrial and electronic equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLow-Temperature Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Capable of operation down to -120°C, according to the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThermal Stability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Described as thermally stable in the Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNon-Combustible Fluid:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The Safety Data Sheet identifies the material as non-combustible.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNo Flash Point:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reported in the manufacturer's technical and safety documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLow Kinematic Viscosity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.32 cSt.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBoiling Point:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 34°C at 1 atm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Greater than 25 kV at a 0.1-inch gap.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNon-Volatile Residue:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Less than 1.0 ppm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eZero Ozone Depletion Potential:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ODP value of 0.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eGlobal Warming Potential:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e GWP value of 530, based on the manufacturer's stated reference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaterial Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible with several metals, plastics, and elastomers, subject to application-specific limitations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications of TMC-7000 Engineered Fluid\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 is designed for industrial heat transfer and low-temperature applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e1. Semiconductor Manufacturing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet identifies TMC-7000 for heat transfer applications in semiconductor manufacturing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. Electronics Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 is listed for electronic applications where a dielectric heat transfer fluid is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. Industrial Heat Transfer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe fluid is used in industrial heat transfer applications, including those identified in the chemical manufacturing industry.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. Low-Temperature Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 is described as capable of operation down to -120°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts Safety Data Sheet also identifies low-temperature immersion baths among its intended uses.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. Additional Manufacturer-Listed Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet lists additional applications, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefrigerant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAerosol Spray Cleaner\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDeposition Coating Solvent\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVapor Degreasing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSpecialty Foam Blowing Additive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLine Flushing for Substances Requiring Special Handling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese applications are listed by TMC Industries and are restricted to professional and industrial use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications of TMC-7000\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe following technical values are taken from the manufacturer's Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eProperty\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eTMC-7000 Specification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTMC-7000 Engineered Fluid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTMC Industries, Inc.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChemical Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMethyl Perfluoropropyl Ether\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCAS Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e375-03-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical State\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eColorless\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMolecular Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 g\/mol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBoiling Point at 1 atm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e34°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFreeze\/Pour Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-122°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid Density\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1400 kg\/m³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKinematic Viscosity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 cSt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVapor Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 kPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLatent Heat of Vaporization\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e142 kJ\/kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoefficient of Thermal Expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0022 K⁻¹\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecific Heat\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1300 J\/kg·K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Conductivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.075 W\/m·K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Tension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.4 dynes\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSolubility of Water in Fluid\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 60 ppmw\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSolubility of Fluid in Water\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 5 ppmw\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Strength at 0.1-inch Gap\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 25 kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVolume Resistivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10⁸ Ohm·cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAutoignition Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e415°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlash Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOzone Depletion Potential (ODP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal Warming Potential (GWP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e530\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAtmospheric Lifetime\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.9 years\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eThe values above are manufacturer-reported typical properties. Unless otherwise specified, values are at 25°C and are not intended for specification purposes. The GWP value uses a 100-year integrated time horizon based on IPCC 2013.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eChemical Composition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's Safety Data Sheet (Version 4.0), TMC-7000 contains:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eChemical Component\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eCAS Number\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eComposition\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMethyl Perfluoropropyl Ether\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e375-03-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 99.5% by weight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eTMC Industries identifies TMC-7000 as a substance rather than a mixture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMaterial Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet identifies compatibility with several metals, plastics, and elastomers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible Metals\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAluminum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCopper\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBrass\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible Plastics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAcrylic (PMMA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolyethylene\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolypropylene\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolycarbonate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolyester\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePEEK\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePTFE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible Elastomers\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEPDM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEPR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePolyurethane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFluorosilicone\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNeoprene\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNitrile Rubber\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eMaterial Compatibility Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTMC Industries notes that compatibility with soft and elastomeric materials depends on the formulation and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 may extract mobile organic compounds, such as plasticizers, from certain polymers. This may cause hardening or shrinking.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe fluid may also be absorbed into some polymers, resulting in swelling, softening, or diffusion through the material.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer identifies possible swelling with prolonged exposure to fluorinated plastics and elastomers, including PTFE, FFKM, and FKM types.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSilicone rubber may also experience absorption and swelling. Some surface oxidation of copper was observed during testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer recommends evaluating material compatibility for each intended application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAvailable Packaging Sizes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 Engineered Fluid is listed in the following packaging options:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003ePackaging Type\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1 Gallon Jug\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 lb \/ 5.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e5 Gallon Pail\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e44 lb \/ 20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e55 Gallon Drum\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e550 lb \/ 250 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSample\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 lb \/ 1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e275 Gallon Tote\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Upon Request\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003ePackaging availability should be confirmed when requesting a quotation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShelf Life and Storage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 has a shelf life of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 years from the date of manufacture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when stored in the original packaging under normal conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer, TMC Industries may re-certify the fluid every 5 years for up to 20 years.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStorage Guidelines\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStore at normal room temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep away from extreme heat.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep containers closed when not in use.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCarefully reseal opened containers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep containers upright to prevent leakage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDo not place containers horizontally or upside down.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse glass or metal containers as identified in the Safety Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep away from strong acids, strong bases, and strong oxidizing agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSafety and Handling Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAccording to the manufacturer's Safety Data Sheet, TMC-7000 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot classified as hazardous under the OSHA Hazard Communication Standard (29 CFR 1910.1200)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHowever, standard handling precautions should still be followed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHandling Precautions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvoid inhalation of vapors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse appropriate protective equipment when required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvoid unnecessary exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDo not eat, drink, or smoke in the work area.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWash exposed skin thoroughly after handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAvoid releasing the fluid into lakes, streams, or sewers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFollow the manufacturer's current Safety Data Sheet for detailed safety and exposure-control information.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIndustrial Use Restrictions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 is restricted to professional and industrial use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer states that the fluid is not intended for use as a medical device or drug.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEnvironmental and Regulatory Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer's Technical Data Sheet reports:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eEnvironmental Property\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eTMC-7000 Value\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOzone Depletion Potential (ODP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal Warming Potential (GWP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e530\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAtmospheric Lifetime\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.9 years\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe Safety Data Sheet also identifies methyl perfluoropropyl ether as listed on the non-confidential portion of the U.S. TSCA Inventory.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRecycling and Disposal\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTMC-7000 Engineered Fluid can be recycled and reused.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTMC Industries provides reclamation services for used fluorinated fluids, as described in its Technical Data Sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFluid Reclamation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer states that reclaimed fluorinated fluids are tested to meet new product specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA Certificate of Analysis is issued with each reclaimed-fluid order.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDisposal Guidelines\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUsed fluid may be reclaimed by TMC Industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIf disposal is required, use an approved facility according to local regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePackaging containing product residue must be disposed of in the same manner as the product.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTMC-7000 Engineered Fluid – Authorized Distributor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an authorized distributor of TMC Industries products, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTMC-7000 Engineered Fluid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor product specifications, packaging options, technical documentation, and quotations related to TMC-7000, contact \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEcontrol Devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSafety Information:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e TMC-7000 is restricted to professional and industrial use. It is not intended for use as a medical device or drug. Review the manufacturer's current Technical Data Sheet, Safety Data Sheet, and product label before handling or using the fluid.\u003c\/span\u003e\u003c\/p\u003e","brand":"Econtroldevices","offers":[{"title":"Default Title","offer_id":47689509077081,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/5659\/2729\/files\/241217_TMC-7000Drum_41ad7d4c-a835-4cbc-81e0-a24fcfa438af.webp?v=1793426466","url":"https:\/\/econtroldevices.com\/products\/tmc-7000-engineered-fluid","provider":"Econtroldevices","version":"1.0","type":"link"}