AD-3283 Fluorinated Engineering Fluid – Industrial Heat Transfer Fluid
Guaranteed Safe Checkout
Econtrol Devices offers AD-3283 Fluorinated Engineering Fluid, a fully fluorinated, non-conductive liquid manufactured by Nantong A.D Dawning Material Co., Ltd. for industrial heat transfer and electronics testing applications.
AD-3283 is designed for semiconductor manufacturing, data centers, aviation electronics, power electronics, and high-performance computing. According to the manufacturer's Technical Data Sheet, the fluid is nonflammable, chemically inert, thermally stable, and has low toxicity.
The supplied product listing positions AD-3283 as a replacement for 3M™ Fluorinert™ FC-3283, offering similar chemistry and physical properties. The product is also identified under the trade names XP-3288 and TF-3288.
Key Features of AD-3283 Fluorinated Engineering Fluid
- Fully Fluorinated Fluid: Developed for industrial heat transfer applications.
- 3M™ Fluorinert™ FC-3283 Replacement: Listed as a replacement with similar chemistry and physical properties.
- Electrically Non-Conductive: Suitable for the electronic applications identified by the manufacturer.
- Thermal Stability: Designed for heat transfer processes in industrial and electronic equipment.
- Chemical Stability: Identified as chemically inert in the Technical Data Sheet.
- Nonflammable: Described as nonflammable in the manufacturer's Technical Data Sheet.
- Low Toxicity: Listed as a product characteristic by the manufacturer.
- Clear, Colorless Liquid: Identified in the Technical Data Sheet.
- Boiling Point: 128°C at 1 atm.
- Dielectric Strength: Greater than 40 kV at a 0.1-inch gap.
- Ozone Depletion Potential: 0.
- Global Warming Potential: Approximately 8600.
Applications of AD-3283 Fluorinated Engineering Fluid
AD-3283 is designed for industrial heat transfer and electronics testing applications.
1. Semiconductor Manufacturing
The manufacturer identifies AD-3283 for heat transfer applications in semiconductor manufacturing.
The supplied product listing also refers to equipment such as:
- Etchers
- Ion Implanters
- Testers
2. Data Center Heat Transfer
AD-3283 is listed for heat transfer applications in data centers.
3. High-Performance Computing
The fluid is intended for heat transfer applications involving high-performance computing equipment.
4. Power Electronics
AD-3283 is identified for use in heat transfer applications involving power electronics.
5. Aviation Electronics
The manufacturer's Technical Data Sheet lists aviation electronics among the intended heat transfer applications.
6. Electronics Testing
AD-3283 is also intended for electronics testing applications.
Technical Specifications of AD-3283
The following values are taken from the manufacturer's AD-3283 Technical Data Sheet.
|
Property |
AD-3283 Specification |
|
Product Name |
AD-3283 Fluorinated Engineering Fluid |
|
Manufacturer |
Nantong A.D Dawning Material Co., Ltd. |
|
CAS Number |
86508-42-1 |
|
Physical Form |
Liquid |
|
Color |
Clear, Colorless |
|
Odor |
Odorless |
|
Average Molecular Weight |
521 g/mol |
|
Boiling Point at 1 atm |
128°C |
|
Pour Point |
-65°C |
|
Calculated Critical Temperature |
235°C |
|
Vapor Pressure |
1.2 kPa |
|
Liquid Density |
1820 kg/m³ |
|
Kinematic Viscosity |
0.75 cSt |
|
Absolute Viscosity |
1.4 cP |
|
Liquid Specific Heat |
1100 J/kg·K |
|
Liquid Thermal Conductivity |
0.066 W/m·K |
|
Refractive Index |
1.28 |
|
Surface Tension |
14.6 mN/m |
|
Volume Resistivity |
10¹⁵ Ohm·cm |
|
Solubility of Water in Fluid |
7 ppm |
|
Dielectric Constant |
1.9 |
|
Dielectric Strength at 0.1-inch Gap |
Greater than 40 kV |
|
Ozone Depletion Potential (ODP) |
0 |
|
Global Warming Potential (GWP) |
Approximately 8600 |
|
Flash Point |
None |
The values above are taken from the manufacturer's Technical Data Sheet and Safety Data Sheet. They represent manufacturer-reported properties and should not be interpreted as guaranteed product specifications.
Chemical Composition
According to the manufacturer's Safety Data Sheet, AD-3283 contains:
|
Component |
CAS Number |
Composition |
|
Perfluoro Compounds, C5–18 |
86508-42-1 |
100% by weight |
The Safety Data Sheet identifies AD-3283 as a fluorinated engineered fluid containing this substance.
Material Compatibility
The manufacturer's Technical Data Sheet identifies AD-3283 as compatible with most metals and plastics, with some limitations involving elastomers.
Metal Compatibility
AD-3283 is described as compatible with most metals.
The manufacturer does not provide a detailed list of individually tested metals in the supplied Technical Data Sheet.
Plastic Compatibility
The fluid is listed as compatible with most plastics.
No individual plastic compatibility table is provided in the supplied Technical Data Sheet.
Elastomer Compatibility
The manufacturer identifies some limitations with elastomeric materials.
For specific material compatibility recommendations, the Technical Data Sheet advises contacting A.D Dawning Material Co.
Available Packaging Sizes
The manufacturer's Technical Data Sheet lists the following packaging options:
|
Packaging Type |
Weight |
Container Capacity |
|
Can |
5 kg |
4 L |
|
Pail |
20 kg |
15 L |
|
Drum |
250 kg |
200 L |
The packaging capacities listed above follow the manufacturer's Technical Data Sheet.
Storage and Handling
AD-3283 is intended for industrial use only.
The manufacturer recommends storing the fluid under appropriate conditions to maintain safe handling and storage.
Storage Guidelines
- Store in a tightly closed container.
- Keep containers in a cool, dry, and well-ventilated area.
- Keep away from heat.
- Keep away from oxidizing agents.
- Keep away from incompatible substances.
- Follow applicable local and national storage regulations.
Handling Precautions
- Use appropriate ventilation during handling.
- Avoid breathing thermal decomposition products.
- Avoid uncontrolled release into the environment.
- Avoid contact with oxidizing agents.
- Wear safety protective glasses.
- Follow the manufacturer's personal protective equipment recommendations.
- Do not eat or smoke while handling the product.
Safety Information
According to the manufacturer's Safety Data Sheet, AD-3283 is not classified as hazardous.
However, the Safety Data Sheet provides precautions for handling, overheating, storage, and disposal.
Thermal Decomposition
At elevated temperatures, possible decomposition products include:
- Carbon Monoxide
- Carbon Dioxide
- Hydrogen Fluoride
Incompatible Materials
The manufacturer's Safety Data Sheet identifies alkali and alkaline earth metals as incompatible materials.
It also states that reactions with strong acids, strong bases, and strong oxidizers may occur at very high temperatures.
Industrial Use Restrictions
AD-3283 is intended for industrial use only.
The manufacturer states that the product is not intended for medical devices, drugs, or food applications.
Environmental and Regulatory Information
The manufacturer reports the following environmental properties for AD-3283:
|
Property |
Reported Value |
|
Ozone Depletion Potential (ODP) |
0 |
|
Global Warming Potential (GWP) |
Approximately 8600 |
According to the Safety Data Sheet, the required components of AD-3283 are listed on the active portion of the U.S. TSCA Inventory.
The SDS also provides chemical inventory compliance information relating to China, Australia, Canada, South Korea, Japan, and the Philippines.
Disposal Information
The manufacturer's Safety Data Sheet recommends disposing of AD-3283 according to applicable local and national regulations.
Disposal Guidelines
- Dispose of waste material at a permitted industrial waste facility.
- Follow applicable local and national waste regulations.
- Ensure any combustion facility is capable of handling hydrogen fluoride.
- Empty and cleaned containers may be disposed of as non-hazardous waste where local regulations permit.
AD-3283 Fluorinated Engineering Fluid – Product Inquiries at Econtrol Devices
Econtrol Devices provides product information and quotation assistance for AD-3283 Fluorinated Engineering Fluid.
For technical specifications, packaging information, and quotations related to AD-3283, contact Econtrol Devices.
Safety Information: AD-3283 is intended for industrial use only and is not intended for medical devices, drugs, or food applications. Review the manufacturer's current Technical Data Sheet, Safety Data Sheet, and product label before handling, storing, or using the fluid.