AD-7100 Fluorinated Engineering Fluid
Guaranteed Safe Checkout
Econtrol Devices offers AD-7100 Fluorinated Engineering Fluid, a clear, colorless fluorinated liquid manufactured by Nantong A.D Dawning Materials Co., Ltd. for industrial cleaning, heat transfer, and electronic applications.
AD-7100 contains methoxy-nonafluorobutane (C₄F₉OCH₃) and is described by the manufacturer as nonflammable, chemically inert, and thermally stable.
The supplied product listing identifies AD-7100 as a replacement for 3M™ Novec™ 7100, offering similar chemistry and physical properties. The product is also listed under the trade names PFE-10, PFE-5100, TF-7100, and SM-7100.
AD-7100 is intended for industrial cleaning and rinsing, heat transfer, dielectric testing, lubricant fluid, and specialty solvent applications.
Key Features of AD-7100 Fluorinated Engineering Fluid
-
3M™ Novec™ 7100 Replacement: Listed as a replacement fluid in the supplied product information.
-
Fluorinated Engineered Fluid: Contains methoxy-nonafluorobutane.
-
Chemically Inert: Described as chemically inert in the manufacturer's Technical Data Sheet.
-
Thermal Stability: Designed for the listed industrial and electronic applications.
-
Nonflammable Fluid: Reported as nonflammable by the manufacturer, with no flash point identified in the Safety Data Sheet.
-
Electronic Cleaning Applications: Intended for industrial cleaning and rinsing.
-
Heat Transfer Applications: Listed as a heat transfer fluid in the Technical Data Sheet.
-
Dielectric Testing: Used as dielectric test media.
-
Low Viscosity: Kinematic viscosity of 0.38 cSt.
-
Boiling Point: 61°C.
-
Ozone Depletion Potential: 0.
-
Global Warming Potential: 300.
Applications of AD-7100 Fluorinated Engineering Fluid
AD-7100 is intended for industrial cleaning, heat transfer, specialty solvent, and electronic applications.
1. Industrial Cleaning and Rinsing
The manufacturer's Technical Data Sheet identifies AD-7100 for cleaning and rinsing applications involving:
-
Heavy oils
-
Grease
-
Fluxes
-
Waxes
-
Surface contamination debris
-
Fluoropolymers
2. Heat Transfer Applications
AD-7100 is listed as a heat transfer fluid for industrial and electronic applications.
The supplied product screenshot also identifies heat transfer applications involving semiconductor manufacturing equipment such as:
-
Etchers
-
Ion Implanters
-
Testers
3. Dielectric Testing
The manufacturer lists AD-7100 for use as dielectric test media.
4. Lubricant Fluid Applications
AD-7100 is identified for lubricant fluid applications in the manufacturer's Technical Data Sheet.
5. Specialty Solvent Applications
The fluid is also listed for use as a specialty solvent.
6. Semiconductor Manufacturing
The supplied product listing describes heat transfer applications involving semiconductor manufacturing equipment.
7. Data Centers and High-Performance Computing
AD-7100 is listed in the supplied product information for heat transfer applications in data centers and high-performance computing equipment.
8. Power Electronics and Avionics
The product listing identifies power electronics and avionics among the intended applications.
Technical Specifications of AD-7100
The following technical specifications are taken from the manufacturer's AD-7100 Technical Data Sheet.
| Property | AD-7100 Specification |
|---|---|
| Product Name | AD-7100 Fluorinated Engineering Fluid |
| Manufacturer | Nantong A.D Dawning Materials Co., Ltd. |
| Chemical Name | Methoxy-nonafluorobutane |
| Chemical Formula | C₄F₉OCH₃ |
| Physical State | Liquid |
| Color | Colorless |
| Average Molecular Weight | 250 g/mol |
| Boiling Point | 61°C |
| Pour Point | -135°C |
| Calculated Critical Temperature | 195°C |
| Vapor Pressure | 26 kPa |
| Liquid Density at 25°C | 1520 kg/m³ |
| Kinematic Viscosity | 0.38 cSt |
| Absolute Viscosity | 0.58 cP |
| Liquid Specific Heat | 1183 J/kg·K |
| Surface Tension | 13.6 mN/m |
| Dielectric Strength | Greater than 40 kV |
| Dielectric Constant at 1 kHz | 7.4 |
| Volume Resistivity | 10⁸ Ohm·cm |
| Solubility of Solvent in Water | 12 ppm |
| Solubility of Water in Solvent | 95 ppm |
| Ozone Depletion Potential (ODP) | 0 |
| Global Warming Potential (GWP) | 300 |
| Flash Point | None |
These are manufacturer-reported technical values and are not guaranteed specifications. The Safety Data Sheet provides additional physical and chemical information.
Chemical Composition
According to the manufacturer's Safety Data Sheet (Version 5.0), AD-7100 contains the following components:
| Chemical Component | CAS Number | Composition |
|---|---|---|
| Methyl Perfluorobutyl Ether | 163702-07-6 | 10–45% by weight |
| Methyl Perfluoroisobutyl Ether | 163702-08-7 | 55–90% by weight |
The Safety Data Sheet identifies AD-7100 as a fluorinated engineered fluid containing these two components.
Material Compatibility
The manufacturer's Technical Data Sheet states that AD-7100 is compatible with most metals and hard polymers.
Metals and Hard Polymers
AD-7100 is identified as compatible with most metals and hard polymers.
The supplied Technical Data Sheet does not provide a detailed list of individually tested metal or polymer grades.
Soft Elastomeric Materials
The manufacturer recommends using soft elastomeric materials containing the least amount of extractable plasticizer.
Fluorinated Plastics and Elastomers
According to the manufacturer, AD-7100 may be absorbed into fluorinated plastics and elastomers during prolonged exposure.
Material compatibility should be assessed according to the intended application, exposure duration, and operating conditions.
Available Packaging Sizes
The manufacturer lists the following packaging options for AD-7100 Fluorinated Engineering Fluid:
| Packaging Type | Weight | Container Capacity |
|---|---|---|
| Can | 5 kg | 4 L |
| Pail | 20 kg | 15 L |
| Drum | 250 kg | 200 L |
These sizes are taken from the manufacturer's Technical Data Sheet.
Storage and Handling
AD-7100 is intended for industrial use only.
Storage Guidelines
-
Store the product in a tightly closed original container.
-
Keep away from strong acids.
-
Keep away from strong bases.
-
Keep away from oxidizing agents.
-
Follow the manufacturer's storage instructions and applicable regulations.
Handling Precautions
-
Avoid inhaling thermal decomposition products.
-
Avoid release to the environment.
-
Avoid contact with oxidizing agents.
-
Do not eat or smoke while handling the product.
-
Use appropriate local exhaust ventilation when extreme overheating may occur.
-
Follow the manufacturer's personal protective equipment recommendations.
Safety Information
According to the manufacturer's Safety Data Sheet, AD-7100 is not classified as hazardous under the OSHA Hazard Communication Standard, 29 CFR 1910.1200.
The manufacturer reports no flash point and identifies the product as nonflammable.
Thermal Decomposition
Under extreme heat or combustion conditions, possible decomposition products include:
-
Carbon Monoxide
-
Carbon Dioxide
-
Hydrogen Fluoride
Occupational Exposure Information
The Safety Data Sheet lists an AIHA time-weighted average (TWA) exposure limit of 750 ppm for each of the two chemical components.
Industrial Use Restrictions
AD-7100 is intended for industrial use only.
The manufacturer states that it is not intended for medical devices, drugs, or consumer applications.
Environmental and Regulatory Information
The manufacturer reports the following environmental properties:
| Property | AD-7100 Value |
|---|---|
| Ozone Depletion Potential (ODP) | 0 |
| Global Warming Potential (GWP) | 300 |
According to the Safety Data Sheet, the required components of AD-7100 are listed on the active portion of the U.S. TSCA Inventory.
The SDS also provides chemical inventory compliance information for Australia, Canada, China, South Korea, Japan, and the Philippines.
Disposal Information
AD-7100 must be disposed of in accordance with applicable local and national regulations.
Disposal Guidelines
-
Dispose of waste material at a permitted industrial waste facility.
-
Follow applicable waste classification and disposal requirements.
-
Ensure combustion facilities can handle hydrogen fluoride.
-
Empty and cleaned containers may be disposed of as non-hazardous waste where permitted.
AD-7100 Fluorinated Engineering Fluid – Product Inquiries at Econtrol Devices
Econtrol Devices provides product information and quotation assistance for AD-7100 Fluorinated Engineering Fluid.
For product specifications, packaging options, and quotations related to AD-7100, contact Econtrol Devices.
Safety Information: AD-7100 is intended for industrial use only and is not intended for medical devices, drugs, or consumer applications. Review the manufacturer's current Technical Data Sheet, Safety Data Sheet, and product label before handling, storing, or using the fluid.