TMC-71IPA Engineered Fluid
Guaranteed Safe Checkout
Econtrol Devices, an authorized distributor of TMC Industries products, offers TMC-71IPA Engineered Fluid, a clear, colorless cleaning solvent developed for precision cleaning, light-duty degreasing, rinsing, and drying applications.
TMC-71IPA is a low-VOC, azeotropic blend formulated without hydrofluorocarbons (HFCs). It is designed as a miscible, drop-in replacement for 3M™ Novec™ 71IPA and is also identified as a substitute for cleaning solvents such as CFC-113 and HCFC-141b.
The fluid is intended for removing particulates, fingerprints, and light soils from metal, plastic, and glass parts. Its low viscosity and cleaning properties make it suitable for applications where light cleaning performance and VOC content are important.
Key Features of TMC-71IPA Engineered Fluid
-
3M™ Novec™ 71IPA Replacement: Listed by TMC Industries as a miscible, drop-in alternative.
-
Light-Duty Cleaning Solvent: Developed for precision cleaning and degreasing applications.
-
Low-VOC Formulation: Described as a low-VOC blend by the manufacturer.
-
HFC-Free Blend: Formulated without hydrofluorocarbons.
-
Azeotropic Blend: Identified as an azeotropic cleaning solvent.
-
Low Viscosity: Kinematic viscosity of 0.44 cSt.
-
Cleaning and Rinsing: Intended to remove particulates, fingerprints, and light soils.
-
Zero Surface Residue: Listed as a product feature by TMC Industries.
-
No Flash Point: Reported in the manufacturer's Technical Data Sheet.
-
Ozone Depletion Potential: ODP value of 0.
-
Boiling Point: 54°C.
-
Material Compatibility: Compatible with many metals, polymers, and elastomers, subject to the manufacturer's compatibility guidance.
Applications of TMC-71IPA Engineered Fluid
TMC-71IPA is intended for light-duty industrial cleaning applications where precision cleaning, rinsing, and drying are required.
1. Precision Cleaning
TMC-71IPA is suitable for cleaning precision parts and components.
The manufacturer identifies applications involving metal, plastic, and glass parts.
2. Light-Duty Degreasing
The fluid is used for light-duty cleaning and degreasing involving:
-
Oils
-
Greases
-
Waxes
3. Cleaning and Rinsing
TMC-71IPA is used to clean and rinse components to remove:
-
Particulates
-
Fingerprints
-
Light Soils
4. Industrial Drying
The manufacturer lists TMC-71IPA for precision cleaning, rinsing, and drying solvent applications.
5. Electronics and Precision Parts
The manufacturer identifies compatibility with materials commonly encountered during cleaning and vapor degreasing of precision parts and electronics.
6. Replacement for 3M Novec 71IPA
TMC-71IPA is offered as a miscible, drop-in replacement for 3M Novec 71IPA.
The manufacturer's Technical Data Sheet also identifies it as a direct substitute for certain solvents, including CFC-113 and HCFC-141b.
Technical Specifications of TMC-71IPA
The following specifications are taken from the manufacturer's Technical Data Sheet and Safety Data Sheet.
| Property | TMC-71IPA Specification |
|---|---|
| Product Name | TMC-71IPA Engineered Fluid |
| Manufacturer | TMC Industries, Inc. |
| Product Series | TMC-71IPA |
| Product Number | 7800 |
| Physical Form | Liquid |
| Color | Colorless |
| Odor | Slight Odor |
| pH | Not Applicable |
| Boiling Point | 54°C |
| Specific Gravity / Density | 1.48 g/mL |
| Kinematic Viscosity | 0.44 cSt |
| Vapor Pressure at 25°C | 207 mmHg |
| Lower Flammability Limit | 4% |
| Upper Flammability Limit | 16.7% |
| Ozone Depletion Potential (ODP) | 0 |
| Flash Point | None |
| Auto-Ignition Temperature | 443°C |
Values are taken from the manufacturer's Technical Data Sheet and Safety Data Sheet. All values are reported at 25°C unless otherwise specified. They are not intended for specification purposes.
Chemical Composition
According to TMC Industries' Safety Data Sheet (Version 2.0), TMC-71IPA is a mixture containing:
| Chemical Component | CAS Number | Composition |
|---|---|---|
| Methyl Perfluoroisobutyl Ether | 163702-08-7 | Greater than 95% by weight |
| Propan-2-ol / Isopropyl Alcohol / Isopropanol | 67-63-0 | Less than 5% by weight |
The manufacturer identifies the product as a mixture rather than a single substance.
Material Compatibility
The manufacturer's Technical Data Sheet lists compatibility with several industrial metals, polymers, and elastomers.
Compatible Metals
TMC-71IPA is described as compatible with:
-
Stainless Steel
-
Aluminum
-
Iron
-
Other metals commonly used in precision parts manufacturing
Compatible Polymers and Elastomers
-
PFA
-
Rexolite
-
Polyester (PET, BET)
-
Polyimide (PI, PEI, PAI)
-
Cast Nylon 6
-
Polyaryletherketone (PEEK)
-
Neoprene
-
Polyphenylene Sulfide (PPS)
-
Polypropylene
-
Polystyrene
-
ABS
-
PTFE / Teflon
-
Polysulfone (PSO)
-
CSPR
-
PVDF
-
EPDM
Incompatible Materials
The manufacturer identifies the following materials as incompatible:
-
Epichlorohydrin
-
Polyphenylene Oxide (PPO)
-
Latex
Material Compatibility Precautions
The manufacturer states that its material compatibility lists are not exhaustive.
TMC Industries recommends trialing all parts for compatibility before introducing a new solvent into full production.
Available Packaging Sizes
TMC-71IPA Engineered Fluid is listed in the following packaging options:
| Packaging Type | Weight |
|---|---|
| 1 Gallon Jug | 10 lb / 4.5 kg |
| 5 Gallon Pail | 50 lb / 22.7 kg |
| 55 Gallon Drum | 551 lb / 250 kg |
| Sample | 2.2 lb / 1 kg |
| 275 Gallon Tote | Available Upon Request |
Packaging availability should be confirmed when requesting a quotation.
Shelf Life and Storage
TMC-71IPA has a shelf life of 5 years from the date of manufacture when stored in its original packaging under normal conditions.
According to TMC Industries, the material can be re-certified every 5 years for up to 20 years.
Storage Guidelines
-
Store in a cool, dry, and well-ventilated place.
-
Keep containers tightly closed.
-
Keep the product in its original packaging.
-
Carefully reseal opened containers and keep them upright to prevent leakage.
-
Protect from direct sunlight.
-
Keep away from strong acids, strong bases, and strong oxidizing agents.
-
Avoid contact with incompatible materials.
Safety and Handling Information
According to the manufacturer's Safety Data Sheet, TMC-71IPA is classified as hazardous under the OSHA Hazard Communication Standard.
Hazard Classification
The Safety Data Sheet identifies:
-
Eye Irritation – Category 2: Causes serious eye irritation.
-
Specific Target Organ Toxicity, Single Exposure – Category 3: May cause drowsiness or dizziness.
The manufacturer also warns that flammable or explosive vapor-air mixtures may form during use, despite no flash point being reported.
Handling Precautions
-
Avoid breathing mist or vapors.
-
Use adequate ventilation.
-
Keep vapor concentrations below applicable occupational exposure limits.
-
Wear suitable protective gloves and clothing.
-
Use safety glasses with side shields or a face shield.
-
Avoid eating, drinking, or smoking in the work area.
-
Follow the manufacturer's current Safety Data Sheet for exposure control and protective equipment requirements.
Recycling and Disposal
TMC-71IPA Engineered Fluid can be recycled and reused.
According to the manufacturer's Technical Data Sheet, TMC Industries provides reclamation services for used fluorinated fluids.
Fluid Reclamation
TMC Industries states that its reclamation process restores used fluorinated fluids to like-new condition.
Reclaimed fluids are tested to meet new product specifications, and a Certificate of Analysis is issued with each order.
Disposal Guidelines
-
Used fluid may be reclaimed by the manufacturer or disposed of at an approved facility.
-
Follow applicable local disposal regulations.
-
Dispose of packaging containing product residue in the same manner as the product.
TMC-71IPA Engineered Fluid – Authorized Distributor
Econtrol Devices is an authorized distributor of TMC Industries products, including TMC-71IPA Engineered Fluid.
For product specifications, packaging options, technical documentation, and quotations related to TMC-71IPA, contact Econtrol Devices.
Safety Information: TMC-71IPA is restricted to professional users. It causes serious eye irritation and may cause drowsiness or dizziness. Flammable or explosive vapor-air mixtures may form during use. Review the manufacturer's current Safety Data Sheet and product label before handling or using the solvent.