Fluorinated Engineering Fluid XP-3288 – Perfluorotripropylamine
Guaranteed Safe Checkout
Econtrol Devices offers Fluorinated Engineering Fluid XP-3288, a fully fluorinated liquid manufactured by Nantong A.D Dawning Material Co., Ltd. for industrial heat transfer and electronics testing applications.
XP-3288, also known as Perfluorotripropylamine, is a clear, colorless liquid used in single-phase heat transfer applications, particularly in semiconductor manufacturing. The supplied product listing identifies XP-3288 as a replacement for 3M™ Fluorinert™ FC-3283, offering similar chemistry and physical properties.
The fluid is also listed under the trade names AD-3283 and TF-3288. Its physical and electrical properties support the industrial applications identified in the manufacturer's technical documentation.
Key Features of XP-3288 Fluorinated Engineering Fluid
- Fully Fluorinated Liquid: Designed for single-phase heat transfer applications.
- 3M™ Fluorinert™ FC-3283 Replacement: Positioned as a replacement in the supplied product listing.
- Clear, Colorless Appearance: Identified in the manufacturer's Technical Data Sheet.
- Heat Transfer Applications: Used in semiconductor manufacturing, data centers, aviation electronics, power electronics, and high-performance computing.
- Electronics Testing: Listed as an intended application by the manufacturer.
- Boiling Point: 128°C at 1 atm.
- Pour Point: -65°C.
- Dielectric Strength: Greater than 40 kV at a 0.1-inch gap.
- Liquid Thermal Conductivity: 0.066 W/m·K.
- Low Ozone Depletion Potential: ODP value of 0.
- Material Identification: Perfluorotripropylamine, CAS 338-83-0.
Applications of XP-3288 Fluorinated Engineering Fluid
XP-3288 is intended for industrial applications involving single-phase heat transfer and electronics testing.
1. Semiconductor Manufacturing
XP-3288 is designed for single-phase heat transfer applications in the semiconductor manufacturing industry.
The supplied product screenshot also lists semiconductor equipment such as:
- Etchers
- Ion Implanters
- Testers
2. Data Center Heat Transfer
The manufacturer's Technical Data Sheet identifies data centers among the intended heat transfer applications.
3. Power Electronics
XP-3288 is listed for heat transfer applications involving power electronics.
4. High-Performance Computing
The manufacturer identifies high-performance computing as an application area for XP-3288 heat transfer fluid.
5. Aviation Electronics
XP-3288 is listed for heat transfer applications involving aviation electronics.
6. Electronics Testing
The manufacturer's Technical Data Sheet identifies electronics testing as an intended use of XP-3288.
Technical Specifications of XP-3288
The following specifications are taken from the manufacturer's XP-3288 Technical Data Sheet.
|
Property |
XP-3288 Specification |
|
Product Name |
Fluorinated Engineering Fluid XP-3288 |
|
Chemical Name |
Perfluorotripropylamine |
|
Manufacturer |
Nantong A.D Dawning Material Co., Ltd. |
|
CAS Number |
338-83-0 |
|
EC Number |
206-420-2 |
|
Physical State |
Liquid |
|
Appearance |
Clear, Colorless |
|
Average Molecular Weight |
521 g/mol |
|
Boiling Point at 1 atm |
128°C |
|
Pour Point |
-65°C |
|
Calculated Critical Temperature |
235°C |
|
Calculated Critical Pressure |
1.22 MPa |
|
Vapor Pressure |
1200 Pa |
|
Latent Heat of Vaporization at Boiling Point |
78 kJ/kg |
|
Liquid Density |
1820 kg/m³ |
|
Kinematic Viscosity |
0.75 cSt |
|
Absolute Viscosity |
1.4 cP |
|
Liquid Specific Heat |
1100 J/kg·K |
|
Liquid Thermal Conductivity |
0.066 W/m·K |
|
Coefficient of Expansion |
0.0014 K⁻¹ |
|
Refractive Index |
1.28 |
|
Surface Tension |
14.6 mN/m |
|
Volume Resistivity |
10¹⁵ Ohm·cm |
|
Dielectric Strength at 0.1-inch Gap |
Greater than 40 kV |
|
Dielectric Constant |
1.9 |
|
Ozone Depletion Potential (ODP) |
0 |
|
Flash Point |
No Flash Point |
All numerical values are based on the manufacturer's supplied Technical Data Sheet and Safety Data Sheet. They should not be treated as guaranteed specifications without confirmation of the applicable test conditions.
Chemical Composition
According to the manufacturer's Safety Data Sheet, XP-3288 contains:
|
Component |
CAS Number |
Concentration |
|
Perfluorotripropylamine |
338-83-0 |
100% |
The Safety Data Sheet identifies the product as Perfluorotripropylamine XP-3288.
Physical and Electrical Properties
Heat Transfer Properties
XP-3288 has a boiling point of 128°C, a pour point of -65°C, and liquid thermal conductivity of 0.066 W/m·K.
The manufacturer lists these properties for its intended single-phase heat transfer applications.
Electrical Properties
The Technical Data Sheet reports the following electrical characteristics:
- Dielectric Strength: Greater than 40 kV at a 0.1-inch gap
- Dielectric Constant: 1.9
- Volume Resistivity: 10¹⁵ Ohm·cm
These values are reported under the manufacturer's specified test conditions.
Available Packaging Sizes
The manufacturer provides the following packaging options:
|
Packaging Type |
Weight |
Container Capacity |
|
Container |
5 kg |
4 L |
|
Container |
20 kg |
15 L |
|
Drum |
250 kg |
200 L |
The supplied product screenshot also displays a 1 kg sample option.
The packaging sizes listed in the product screenshot should be confirmed against the manufacturer documentation when selecting the required quantity.
Storage and Handling
XP-3288 is intended for industrial use only.
The manufacturer recommends storing the fluid in suitable conditions to maintain proper handling and storage practices.
Storage Guidelines
- Store in a tightly closed container.
- Keep containers in a cool, dry, and well-ventilated area.
- Keep away from fire and heat sources.
- Protect from direct sunlight.
- Store away from incompatible substances, food, and food containers.
- Follow relevant national and local storage regulations.
Handling Precautions
- Use appropriate ventilation.
- Avoid breathing vapor, mist, or dust.
- Avoid contact with eyes and skin.
- Keep away from open flames, sparks, and static electricity.
- Use appropriate chemical-resistant gloves and eye protection.
- Wash hands and face thoroughly after handling.
- Do not eat, drink, or smoke while handling the product.
Safety Information
According to the manufacturer's Safety Data Sheet, XP-3288 is not classified as hazardous.
However, the document also includes precautions related to heating, fire conditions, ventilation, and personal protection.
Safety Precautions
- Avoid exposure to high temperatures and ignition sources.
- Do not expose sealed containers to excessive heat.
- Avoid uncontrolled release into the environment.
- Use adequate ventilation in enclosed areas.
- Follow the manufacturer's Safety Data Sheet for protective equipment requirements.
Industrial Use Restrictions
The manufacturer identifies XP-3288 as intended for industrial use only.
The product is not intended for use in medical devices or drugs.
Environmental and Disposal Information
The manufacturer's Technical Data Sheet reports an ozone depletion potential of 0 for XP-3288.
The Safety Data Sheet recommends preventing uncontrolled release to the environment.
Disposal Guidelines
- Dispose of waste according to applicable national and local regulations.
- Use a qualified hazardous waste treatment company where required.
- Do not release the product into drains.
- Return empty containers to the supplier for recycling where possible.
- Dispose of contaminated packaging according to applicable regulations.
XP-3288 Fluorinated Engineering Fluid – Product Inquiries at Econtrol Devices
Econtrol Devices provides product information and quotation assistance for Fluorinated Engineering Fluid XP-3288.
For inquiries regarding technical specifications, packaging options, and XP-3288 Fluorinated Engineering Fluid, contact Econtrol Devices.
Safety Information: XP-3288 is intended for industrial use only and is not intended for medical devices or drugs. Review the manufacturer's current Safety Data Sheet and Technical Data Sheet before handling, storing, or using the product.