Econtrol Devices offers product information and quotation assistance for Opteon™ SF33 Specialty Fluid, a hydrofluoroolefin (HFO) solvent developed by The Chemours Company for industrial cleaning, degreasing, drying, and heat transfer applications.
Opteon SF33, also identified as HFO-1336mzz-Z, is a clear, colorless specialty fluid with zero ozone depletion potential (ODP) and a global warming potential (GWP) of 2, based on a 100-year integration time horizon.
The fluid is designed for metal degreasing, precision cleaning, electronics cleaning, and industrial solvent applications. Its low viscosity, thermal stability, and nonflammable properties make it suitable for cleaning and heat transfer processes.
According to Chemours, Opteon SF33 is intended as a replacement for PFCs, HCFCs, PFPEs, HFCs, and HFEs in industrial solvent applications.
Key Features of Opteon SF33 Specialty Fluid
- Hydrofluoroolefin (HFO) Specialty Fluid: Identified as HFO-1336mzz-Z.
- Low Global Warming Potential: GWP value of 2 over a 100-year integration period.
- Zero Ozone Depletion Potential: ODP value of 0.
- Nonflammable Fluid: No flash point reported under ASTM D56 and ASTM D1310 testing.
- Low Viscosity: 0.38 cP at 25°C.
- Boiling Point: 33.4°C.
- Thermal Stability: Stable under normal conditions, according to the manufacturer.
- Clear, Colorless Liquid: Identified in the manufacturer documentation.
- Industrial Cleaning Applications: Used for degreasing, electronics cleaning, precision cleaning, and rinsing.
- Heat Transfer Applications: Listed as a heat transfer agent in the Safety Data Sheet.
- Recoverable Solvent: The manufacturer identifies the fluid as recoverable through distillation equipment.
Applications of Opteon SF33 Specialty Fluid
Opteon SF33 is designed for industrial cleaning, solvent, and heat transfer applications.
1. Metal Degreasing
Opteon SF33 is used for industrial metal degreasing applications.
The manufacturer reports compatibility testing with stainless steel, copper, brass, aluminum, and carbon steel.
2. Electronics Cleaning
The fluid is listed for electronics cleaning applications where industrial cleaning solvents are required.
3. Precision Cleaning
Opteon SF33 is developed for precision cleaning applications involving compatible industrial materials.
4. Cleaning and Rinsing
The manufacturer lists the fluid as a cleaning and rinsing agent.
5. Aerosol Solvent Applications
Opteon SF33 is identified for use as an aerosol solvent in the Technical Bulletin.
6. Heat Transfer Applications
The fluid is listed as a heat transfer agent in the manufacturer's Safety Data Sheet.
7. Industrial Solvent Replacement
Opteon SF33 is identified as a replacement for the following solvent categories in industrial applications:
- Perfluorocarbons (PFCs)
- Hydrochlorofluorocarbons (HCFCs)
- Perfluoropolyethers (PFPEs)
- Hydrofluorocarbons (HFCs)
- Hydrofluoroethers (HFEs)
Technical Specifications of Opteon SF33
The following technical values are taken from the manufacturer's Technical Bulletin.
|
Property |
Opteon SF33 Specification |
|
Product Name |
Opteon™ SF33 Specialty Fluid |
|
Manufacturer |
The Chemours Company FC, LLC |
|
Chemical Identification |
HFO-1336mzz-Z |
|
Chemical Name |
(Z)-1,1,1,4,4,4-Hexafluoro-2-butene |
|
CAS Number |
692-49-9 |
|
Chemical Structure |
cis-CF₃CH=CHCF₃ |
|
Physical State |
Liquid |
|
Color |
Clear, Colorless |
|
Molecular Weight |
164 g/mol |
|
Boiling Point |
33.4°C |
|
Freezing Point |
-107°C |
|
Density at 25°C |
1.36 g/cm³ |
|
Viscosity at 25°C |
0.38 cP |
|
Kb Value |
11.3 |
|
Dipole Moment |
2.9688 D |
|
Vapor Pressure at 25°C |
0.07 MPa |
|
Water Solubility |
560 ppm |
|
Critical Temperature |
171.3°C |
|
Critical Pressure |
2.9 MPa |
|
Critical Density |
0.471 g/cm³ |
|
Heat of Vaporization at Boiling Point |
166 kJ/kg |
|
Liquid Thermal Conductivity at 25°C |
0.077 W/m·K |
|
Liquid Specific Heat at 25°C |
1.2 kJ/kg·K |
|
Surface Tension |
0.013 N/m |
|
Dielectric Constant |
32 |
|
Electrical Resistivity |
10⁸ Ohm-cm |
|
Breakdown Voltage |
10 kV |
|
Global Warming Potential (GWP) |
2 |
|
Ozone Depletion Potential (ODP) |
0 |
|
Occupational Exposure Limit (OEL) |
500 ppm |
|
Flash Point |
None |
These are manufacturer-reported technical values. They are not intended to replace product-specific specifications or the Safety Data Sheet.
Chemical Composition
According to the manufacturer's Safety Data Sheet, Opteon SF33 is identified as a substance containing:
|
Property |
Details |
|
Chemical Name |
(Z)-1,1,1,4,4,4-Hexafluoro-2-butene |
|
CAS Number |
692-49-9 |
|
Composition |
90–100% by weight |
|
Substance Type |
Hydrofluoroolefin (HFO) |
The exact concentration is withheld as a trade secret, as stated in the manufacturer's Safety Data Sheet.
Material Compatibility
Chemours provides compatibility testing for Opteon SF33 with various metals, plastics, and elastomers.
Compatible Metals
The manufacturer reports good stability following two weeks of testing at 100°C with the following metals:
- Aluminum
- Copper
- Brass
- Stainless Steel
- Carbon Steel
The tests reported no weight loss or change in surface appearance for these metals.
Plastic Compatibility
The manufacturer's Technical Bulletin lists testing with the following plastics:
- ABS
- High Impact Polystyrene (HIPS)
- PET
- Polystyrene (PS)
- PVC
- CPVC
- PTFE
- ETFE
- POM
- PEEK
- Liquid Crystal Polyester (LCP)
- Polyetherimide (PEI)
- PVDF
- Polypropylene (PP)
- High-Density Polyethylene (HDPE)
Testing at room temperature for two weeks showed good compatibility with most plastics.
Elastomer Compatibility
The manufacturer provides compatibility data for:
- Natural Rubber (NR)
- Polychloroprene (CR)
- Acrylonitrile Butadiene Rubber (NBR)
- Fluoroelastomer (FKM)
- Thiokol
- Isobutylene Isoprene Rubber (IIR)
- EPDM
- Chlorosulfonated Polyethylene (CSM)
The manufacturer notes that some reversible swelling is expected with partially fluorinated elastomers.
Material Compatibility Precautions
Chemours advises against contact with strong bases, strong Lewis acids such as aluminum trichloride, alkali and alkaline earth metals, powdered metals, and powdered metal salts.
Material compatibility should be evaluated for the intended industrial application.
Storage and Handling
Opteon SF33 is intended for use in industrial installations only.
According to Chemours, the fluid is thermally stable under recommended storage conditions and does not oxidize or degrade during storage.
Storage Guidelines
- Store in a clean, dry area.
- Keep away from direct sunlight.
- Protect from freezing temperatures.
- Do not expose stored product to temperatures above 46°C (115°F).
- Keep in properly labeled containers.
- Use adequate ventilation during handling.
- Use drum pumps when dispensing from pails or drums containing 5 gallons or more, as recommended in the Safety Data Sheet.
Handling Precautions
- Follow good industrial hygiene and safety practices.
- Minimize release to the environment.
- Use appropriate protective equipment based on workplace exposure.
- Maintain adequate ventilation, especially in confined areas.
- Follow the manufacturer's Safety Data Sheet for personal protective equipment and exposure controls.
Safety and Environmental Properties
The manufacturer identifies Opteon SF33 as a nonflammable HFO specialty fluid.
The Safety Data Sheet states that the product is not classified as hazardous under the OSHA Hazard Communication Standard.
Environmental Properties
- Ozone Depletion Potential: 0
- Global Warming Potential: 2 (100-year ITH)
Safety Considerations
The Safety Data Sheet warns that vapors are heavier than air and may reduce oxygen available for breathing.
Rapid evaporation may also cause frostbite. Misuse or intentional inhalation abuse may result in serious cardiac effects.
Appropriate ventilation and safe handling practices must be followed.
Recycling and Disposal
Opteon SF33 can be recovered through off-line and in-line distillation equipment, as described in the manufacturer's Technical Bulletin.
The manufacturer also identifies vapor degreasing equipment with vapor containment technology for safe and economical solvent use.
Spent solvent that cannot be recycled should be tested and classified for disposal.
Waste fluid and contaminated packaging must be handled in accordance with applicable regulations.
Available Packaging Options
The supplied product screenshot lists the following packaging options:
|
Packaging Type |
Weight |
|
1 Gallon Jug |
10 lb / 4.5 kg |
|
5 Gallon Pail |
50 lb / 22.7 kg |
|
15 Gallon Drum |
500 lb / 228 kg |
|
Sample |
2.2 lb / 1 kg |
Packaging availability and quantities should be confirmed when requesting a quotation.
Opteon SF33 Specialty Fluid – Product Inquiries at Econtrol Devices
Econtrol Devices provides product information and quotation assistance for Opteon™ SF33 Specialty Fluid and other industrial fluid requirements.
For technical specifications, packaging information, and product inquiries related to Opteon SF33, contact Econtrol Devices.
Safety Information: Opteon SF33 is intended for industrial installations only. Review the manufacturer's current Safety Data Sheet, Technical Bulletin, and product label before handling or using the fluid.